Home chevron_right Instruments & Meters chevron_right Gas Detector 
New Material R&D Laboratory Boron Trichloride Alarm BCl₃ Leak Detection Alarm SKA/NE-301 (BCL3)
New Material R&D Laboratory Boron Trichloride Alarm BCl₃ Leak Detection Alarm

New Material R&D Laboratory Boron Trichloride Alarm BCl₃ Leak Detection Alarm - SKA/NE-301 (BCL3)

Adopts UK-imported intelligentECsensor, intrinsically safe technology, can support multi-gas and multi-range detection, and can provide customized products according to user needs;

Product Model: SKA/NE-301 (BCL3)

Product Introduction

New Material R&D Laboratory Boron Trichloride Alarm BCl₃ Leak Detection Alarm

1. Core detection parameters

Detection gas: boron trichloride (BCl₃, high-purity industrial toxic gas)

Detection principle: high-performance four-electrode electrochemical sensing principle, high precision, strong stability, good anti-interference, specially adapted for boron trichloride toxic gas detection

Optional ranges: conventional0-10ppm、0-50ppm(recommended range for conventional industrial safety monitoring), customizable0-100ppm、1000ppm、2000ppm、6000ppmmultiple specifications

Resolution:0-10ppm/50ppmRange:0.001ppm;0-1000ppmRange:0.01ppm;1000ppmAbove range:1ppm

Measurement accuracy:≤±2%F.S(high-precision model)/≤±3%F.S(conventional industrial model), fully superior to national standard detection error requirements

Repeatability:≤±1%FS, minimal data fluctuation, stable long-term monitoring data

Response time:T90≤20seconds, ultra-fast capture of gas leakage, rapid warning

Alarm threshold (industry standard): first-level low alarm5ppm(OSHAoccupational exposure limit), second-level high alarm10ppm, customizable threshold adjustment

2. Hardware protection and working condition parameters

Explosion-proof grade:ExdⅡCT6 Gb explosion-proof type, suitable for high-risk explosion-proof workshops, complies with industrial explosion-proof safety specifications

Protection rating:IP67, comprehensive waterproof, dustproof, short-term rainproof, acid and alkali corrosion resistance, suitable for outdoor, humid, and dusty harsh working conditions

Structure and process: nano anti-corrosion coating on the body, anti-aging, anti-exposure, resistant to industrial corrosion; built-in industrial-gradeEMCmodule, second-level lightning protection, resistance to strong magnetic and electrostatic interference

Operating temperature:-32℃~+50℃, wide temperature operation, suitable for different working conditions in north and south plants

Sensor life: conventional working conditions2-3years, up to in high-quality working conditions3-8years, long service life and low operation and maintenance cost

Detection method: diffusion type as standard, optional pump-suction type, flow-through type, pipeline type, suitable for detection in confined spaces, pipelines, and open workshop areas

Installation method: conventional wall-mounted installation, supports pipeline-type and flange-type customized installation, suitable for various plant layouts

New Material R&D Laboratory Boron Trichloride Alarm BCl₃ Leak Detection Alarm

3. Signal output and intelligent functions

Output signal: standard three-wire4-20mAAnalog signal,RS485-RTUdigital signal, supports0-5Vvoltage output, multiple signals adapt to different security systems

Linkage function: optional1-2set passive/active contact output, can link fans, solenoid valves, and spray equipment to achieve automatic exhaust and gas source shutoff upon leakage

Display method: high-definition backlightLCDdigital display screen, real-time display of gas concentration, alarm status, and equipment fault information, intuitive and clear data visualization

Alarm method: high-decibel audible and visual dual alarm, immediate reminder when exceeding the limit, suitable for noisy industrial workshop environments

Intelligent functions: full-range automatic temperature and humidity compensation, data correction; automatic equipment fault self-check; historical data storage and traceability, supports remote data upload

4. Electrical and installation parameters

Electrical interface: standard3/4NPT, optionalM20×1.5internal thread,1/2NPT, suitable for conventional industrial wiring interfaces

Wiring specifications:4-20mAThe signal uses three-core shielded cable,RS485The signal uses four-core shielded cable, ultra-1000recommended wire diameter for meter wiring≥1.5mm, shielding layer grounding ensures stable signal

New Material R&D Laboratory Boron Trichloride Alarm BCl₃ Leak Detection Alarm

5. Implementation standards and applicable scenarios

Compliance: Strictly follow national standardsGB 12358-2024"Combustible Gas Detection Alarm" industrial detection standard, performance superior to national standard requirements, worry-free compliance for safety supervision, annual inspection, and acceptance

Applicable scenarios: widely used in semiconductor manufacturing, photovoltaic industry, fine chemicals, new material research and development, special gas storage workshops, laboratories, and other places with boron trichloride leakage risks, focusing on toxic gas leakage monitoring to avoid risks of personnel poisoning, equipment corrosion, and plant safety accidents

 

Main Application Areas

  • Semiconductor Manufacturing — Detects boron trichloride leaks during doping and etching processes to ensure worker safety and process integrity.
  • New Material R&D Laboratories — Monitors BCl₃ levels in experimental setups to protect researchers and maintain a safe environment.
  • Chemical Production — Provides continuous leak detection in boron trichloride production and handling facilities to prevent toxic exposure.
  • Pharmaceutical Industry — Ensures safe handling of BCl₃ in pharmaceutical synthesis by monitoring airborne concentrations.
  • Metallurgical Processes — Detects BCl₃ leaks in metal refining and alloy production to avoid hazardous conditions.

Keywords:boron trichloride alarm, BCl3 gas detector, BCl3 leak detection, online gas alarm, electrochemical sensor, industrial gas monitor, BCl3 safety system, toxic gas alarm