Home chevron_right Transmitter chevron_right Gas Transmitter 
Freon Chilled Water Area Monitoring Terminal Industrial Chilled Water System Fixed Safety Monitoring SKA/FLA-BJQ
Freon Chilled Water Area Monitoring Terminal Industrial Chilled Water System Fixed Safety Monitoring

Freon Chilled Water Area Monitoring Terminal Industrial Chilled Water System Fixed Safety Monitoring - SKA/FLA-BJQ

• Detected gas: Freon (refrigerant, R22/R134a/R410A optional)

• Measuring range: 0~1000ppm

• Resolution: 1ppm

• Alarm point: 500ppm (customizable)

• Accuracy: ±3%FS

• Response time: T90 ≤30s

• Zero drift: ≤±2%FS/year
 

Product Model: SKA/FLA-BJQ

Product Introduction

Freon Chilled Water Area Monitoring Terminal Industrial Chilled Water System Fixed Safety Monitoring - Product Overview
The Freon chilled water area monitoring terminal is a gas detection terminal device used for fixed safety monitoring of industrial chilled water systems. Search keywords: Freon chilled water area monitoring terminal, industrial chilled water system fixed safety monitoring, Freon alarm. The terminal is fixedly installed in the chilled water area and can continuously detect Freon concentration. When the concentration exceeds the set value, it emits sound and light alarms and outputs linkage signals to control ventilation and shutoff equipment. In fixed safety monitoring of industrial chilled water systems, the Freon chilled water area monitoring terminal can reflect in real time the leakage risks of chilled water pumps, heat exchangers, and pipeline valves, ensuring the safety of personnel and facilities.

Freon Chilled Water Area Monitoring Terminal Industrial Chilled Water System Fixed Safety Monitoring - Working Principle
The Freon chilled water area monitoring terminal uses semiconductor sensors or infrared sensors to detect Freon concentration and output electrical signals, which are processed by a microprocessor to determine whether to alarm. In fixed safety monitoring of industrial chilled water systems, the Freon chilled water area monitoring terminal supports RS485, 4-20mA, and Modbus outputs, and can be connected to PLC, DCS, and gas alarm control systems. The terminal is fixedly installed near chilled water pumps or heat exchangers, has an explosion-proof enclosure and a high protection rating, and is suitable for low-temperature and explosion-proof environments in chilled water systems.

Freon Chilled Water Area Monitoring Terminal Industrial Chilled Water System Fixed Safety Monitoring - Application Scenarios
The Freon chilled water area monitoring terminal is widely used in the chilled water pump, heat exchanger, water storage tank, and pipeline valve areas of industrial chilled water systems. In fixed safety monitoring of industrial chilled water systems, the Freon chilled water area monitoring terminal can be fixedly installed near chilled water pumps, pipeline valves, and personnel inspection passages. The terminal can be linked with exhaust fans, shutoff valves, and fire protection systems to achieve automatic handling. For large chilled water systems, the Freon chilled water area monitoring terminal can also form a multi-point monitoring network and upload data uniformly to the control center.

Freon Chilled Water Area Monitoring Terminal Industrial Chilled Water System Fixed Safety Monitoring - Technical Advantages
The Freon chilled water area monitoring terminal has advantages such as easy installation, continuous monitoring, and flexible linkage. In fixed safety monitoring of industrial chilled water systems, the Freon chilled water area monitoring terminal uses industrial-grade sensors and explosion-proof design, making it suitable for long-term operation. The terminal supports sound and light alarms, fault self-diagnosis, and remote output, and is easy to maintain. When selecting a Freon chilled water area monitoring terminal, attention should be paid to detection range, accuracy, response time, explosion-proof rating, and output method to ensure reliable and effective fixed safety monitoring of industrial chilled water systems.