Alarms for heat pump units, real-time monitoring of Freon leakage - SKA/NE-301(R 134 a)
Mainstream adoptionNDIR non-dispersive infrared sensor(Most commonly used industrial fixed type): Freon absorbs infrared light at a specific wavelength, and the sensor detects changes in light intensity to convert it into gas concentration, with high accuracy, resistance to water vapor, and long service life;
Product Introduction
Alarms for heat pump units, real-time monitoring of Freon leakage
Freon alarm, also called refrigerant / refrigerant detector, specifically used to detect the leakage concentration of Freon (R22/R134a/R404A/R410A/R32, etc.) in the air. Freon is colorless and odorless, and the human eye cannot directly detect leaks. After leakage, it can easily cause personnel hypoxia and suffocation; refrigerants such as R32 are also flammable and pose an explosion risk when encountering open flames, while also causing refrigerant loss and environmental pollution. Therefore, cold storage, refrigeration rooms, and central air-conditioning rooms need to install monitoring.
Mainstream adoptionNDIR non-dispersive infrared sensor (most commonly used in industrial fixed installations): Freon absorbs infrared light at specific wavelengths, and the sensor detects changes in light intensity to convert into gas concentration, with high accuracy, resistance to moisture, and long service life;
Alarms for heat pump units, real-time monitoring of Freon leakage
Freon alarm (refrigerant leakage alarm)
Freon alarm, also called refrigerant / refrigerant detector, specifically used to detect the leakage concentration of Freon (R22/R134a/R404A/R410A/R32, etc.) in the air. Freon is colorless and odorless, and the human eye cannot directly detect leaks. After leakage, it can easily cause personnel hypoxia and suffocation; refrigerants such as R32 are also flammable and pose an explosion risk when encountering open flames, while also causing refrigerant loss and environmental pollution. Therefore, cold storage, refrigeration rooms, and central air-conditioning rooms need to install monitoring.
✅ Working principle
Mainstream adoptionNDIR non-dispersive infrared sensor (most commonly used in industrial fixed installations): Freon absorbs infrared light at specific wavelengths, and the sensor detects changes in light intensity to convert into gas concentration, with high accuracy, resistance to moisture, and long service life;
Also semiconductor / halogen heated diode, mostly used in handheld leak detectors, suitable for on-site leak location;
The fixed complete set consists of a detector (on-site probe)+ alarm controller (main unit); the detector collects concentration signals and transmits them to the main unit; when concentration reaches low alarm and high alarm thresholds, the main unit triggers sound and light alarms, and can link to exhaust ventilation, cut off the refrigerant solenoid valve, and shut down the refrigeration unit; some support remote mobile phone / monitoring room alarms.
📌 Product Categories
Fixed Freon alarm (industrial mainstream)
24-hour online continuous monitoring, wall-mounted installation, used in cold storage, refrigeration rooms, data center air-conditioning rooms, large supermarket cold cabinet rooms; supports 4-20mA, RS485 signal access to PLC / fire protection systems, explosion-proof models used in hazardous areas.
Portable handheld leak detector
With a flexible gooseneck probe, used by maintenance personnel for inspections and leak detection; used to find tiny leaks in pipeline valves and flanges, not for long-term online monitoring.
Standalone simple alarm
Plug and play, with built-in sound and light, simple monitoring for small machine rooms and small air-conditioning machine rooms.
🧪 Detectable refrigerants
R22, R134a, R404A, R407C, R410A, R507, R32 and other halogenated hydrocarbon refrigerants (Freon-type refrigerants).
📍 Installation points (very critical)
Freon has different densities, so installation heights differ:
R22, R404A (heavier than air): detector 0.3~0.6m above the ground, sensor facing downward;
R410A, R134a, R32 (lighter than air): the detector is installed 0.3~0.6m below the ceiling;
Probes should preferably be arranged near compressors, valves, flanges, pipe joints, and other locations most prone to leakage;
The controller (main unit) is installed in the duty room, about [distance] above the ground 1.5 meters, convenient for personnel to inspect.
Alarms for heat pump units, real-time monitoring of Freon leakage
⚠️ Main function
Safety warning: sound and light alarm when leakage exceeds the standard, preventing hypoxia and suffocation in enclosed spaces;R32 flammable refrigerant can prevent explosion risks;
Linkage control: automatically turn on exhaust fans, cut off the refrigerant pipeline solenoid valve, and shut down the machine to reduce leakage;
Reduce economic losses: early leak detection avoids massive refrigerant loss and refrigeration unit damage;
Main Application Areas
- Cold Storage Rooms — Detect refrigerant leaks to prevent oxygen depletion and ensure worker safety in low-temperature environments.
- Refrigeration Machine Rooms — Continuous monitoring of Freon concentration to avoid explosion risks and equipment damage.
- Central Air Conditioning Plants — Real-time leak detection for R134a and other refrigerants to maintain efficient cooling and environmental compliance.
- Heat Pump Units — Monitor Freon leakage in heat pump systems to prevent performance loss and safety hazards.
- Industrial Refrigeration Systems — Protect large-scale refrigeration systems from refrigerant loss and ensure regulatory compliance.
Keywords:freon leak detector, refrigerant gas alarm, R134a leak monitor, NDIR freon sensor, heat pump leak alarm, industrial gas detector, refrigeration leak alarm, freon gas monitor