Home chevron_right Instruments & Meters chevron_right Gas Detector 
Real-time leak detection! Freon gas alarm online detection SKA/NE-301(R 134 a)
Real-time leak detection! Freon gas alarm online detection

Real-time leak detection! Freon gas alarm online detection - SKA/NE-301(R 134 a)

Mainstream adoptionNDIR non-dispersive infrared sensor(Most commonly used industrial fixed type): Freon absorbs infrared light at a specific wavelength, and the sensor detects changes in light intensity to convert it into gas concentration, with high accuracy, resistance to water vapor, and long service life;

Product Model: SKA/NE-301(R 134 a)

Product Introduction

Real-time leak detection! Freon gas alarm online detection

Freon alarm, also called refrigerant / refrigerant detector, specifically used to detect the leakage concentration of Freon (R22/R134a/R404A/R410A/R32, etc.) in the air. Freon is colorless and odorless, and the human eye cannot directly detect leaks. After leakage, it can easily cause personnel hypoxia and suffocation; refrigerants such as R32 are also flammable and pose an explosion risk when encountering open flames, while also causing refrigerant loss and environmental pollution. Therefore, cold storage, refrigeration rooms, and central air-conditioning rooms need to install monitoring.

 

Mainstream adoptionNDIR non-dispersive infrared sensor (most commonly used in industrial fixed installations): Freon absorbs infrared light at specific wavelengths, and the sensor detects changes in light intensity to convert into gas concentration, with high accuracy, resistance to moisture, and long service life;

Real-time leak detection! Freon gas alarm online detection

Freon alarm (refrigerant leakage alarm)

Freon alarm, also called refrigerant / refrigerant detector, specifically used to detect the leakage concentration of Freon (R22/R134a/R404A/R410A/R32, etc.) in the air. Freon is colorless and odorless, and the human eye cannot directly detect leaks. After leakage, it can easily cause personnel hypoxia and suffocation; refrigerants such as R32 are also flammable and pose an explosion risk when encountering open flames, while also causing refrigerant loss and environmental pollution. Therefore, cold storage, refrigeration rooms, and central air-conditioning rooms need to install monitoring.

✅ Working principle

Mainstream adoptionNDIR non-dispersive infrared sensor (most commonly used in industrial fixed installations): Freon absorbs infrared light at specific wavelengths, and the sensor detects changes in light intensity to convert into gas concentration, with high accuracy, resistance to moisture, and long service life;

Also semiconductor / halogen heated diode, mostly used in handheld leak detectors, suitable for on-site leak location;

The fixed complete set consists of a detector (on-site probe)+ alarm controller (main unit); the detector collects concentration signals and transmits them to the main unit; when concentration reaches low alarm and high alarm thresholds, the main unit triggers sound and light alarms, and can link to exhaust ventilation, cut off the refrigerant solenoid valve, and shut down the refrigeration unit; some support remote mobile phone / monitoring room alarms.

📌 Product Categories

Fixed Freon alarm (industrial mainstream)

24-hour online continuous monitoring, wall-mounted installation, used in cold storage, refrigeration rooms, data center air-conditioning rooms, large supermarket cold cabinet rooms; supports 4-20mA, RS485 signal access to PLC / fire protection systems, explosion-proof models used in hazardous areas.

Portable handheld leak detector

With a flexible gooseneck probe, used by maintenance personnel for inspections and leak detection; used to find tiny leaks in pipeline valves and flanges, not for long-term online monitoring.

Standalone simple alarm

Plug and play, with built-in sound and light, simple monitoring for small machine rooms and small air-conditioning machine rooms.

🧪 Detectable refrigerants

R22, R134a, R404A, R407C, R410A, R507, R32 and other halogenated hydrocarbon refrigerants (Freon-type refrigerants).

📍 Installation points (very critical)

Freon has different densities, so installation heights differ:

R22, R404A (heavier than air): detector 0.3~0.6m above the ground, sensor facing downward;

R410A, R134a, R32 (lighter than air): the detector is installed 0.3~0.6m below the ceiling;

Probes should preferably be arranged near compressors, valves, flanges, pipe joints, and other locations most prone to leakage;

The controller (main unit) is installed in the duty room, about [distance] above the ground 1.5 meters, convenient for personnel to inspect.

Real-time leak detection! Freon gas alarm online detection

⚠️ Main function

Safety warning: sound and light alarm when leakage exceeds the standard, preventing hypoxia and suffocation in enclosed spaces;R32 flammable refrigerant can prevent explosion risks;

Linkage control: automatically turn on exhaust fans, cut off the refrigerant pipeline solenoid valve, and shut down the machine to reduce leakage;

Reduce economic losses: early leak detection avoids massive refrigerant loss and refrigeration unit damage;

 

Main Application Areas

  • Cold Storage Facilities — Monitor refrigerant leaks in cold storage and refrigeration rooms to prevent asphyxiation and product loss.
  • HVAC Machine Rooms — Detect Freon leaks in central air conditioning and chiller plants to ensure safe operation.
  • Industrial Refrigeration — Continuous leak monitoring in industrial refrigeration systems using R22, R134a, R404A, R410A, or R32.
  • Commercial Kitchens — Protect commercial refrigeration equipment and staff from refrigerant leaks in restaurants and supermarkets.
  • Chemical Plants — Monitor Freon gas in chemical processing areas where refrigerants are used or stored.

Keywords:freon gas alarm, refrigerant leak detector, R134a gas detector, NDIR freon sensor, industrial gas alarm, cold storage leak monitor, HVAC refrigerant alarm, freon leak detection system