Home chevron_right Sensors chevron_right Gas sensors chevron_right Ammonia gas sensors 
UK alphasense three-electrode electrochemical ammonia gas sensor (NH3 sensor) NH3-A1
UK alphasense three-electrode electrochemical ammonia gas sensor (NH3 sensor)
UK alphasense three-electrode electrochemical ammonia gas sensor (NH3 sensor)

UK alphasense three-electrode electrochemical ammonia gas sensor (NH3 sensor) - NH3-A1

Is an electrochemical sensor
Linear output
Can be used in harsh environments
High sensitivity
3-electrode, 4-series size

Product model: NH3-A1

Product introduction

I. ElectrochemicalAmmonia gas sensors(NH3 sensor) NH3-A1 product description:

Ammonia gas sensorsNH3-A1 is mainly used to detect the concentration of ammonia in the atmosphere. NH3-A1 is a 3-electrode electrochemical ammonia gas sensor with linear current output, easy signal processing, high sensitivity, suitable for harsh environments such as poultry farms, pig farms, and other fields.


II. Electrochemical ammonia gas sensor (NH3 sensor) NH3-A1 main parameters
Overload: 1000ppm
Response time: < 60s
Dimensions: Φ20.2×16.5
Ammonia detection range: 0-200ppm
Sensitivity: 17 to 27 nA/ppm


III. Electrochemical ammonia gas sensor (NH3 sensor) NH3-A1 typical applications
Ammonia gas transmitters, various ammonia detection occasions


IV. Electrochemical ammonia gas sensor (NH3 sensor) NH3-A1Performance:

Sensitivity 50ppmNH3,nA/ppm 17~27
Response time t90 from zero to 50ppm NH3 (s) <60
Zero current ppm in zero air <20
Resolution Average noise (ppm) <0.3
Range NH3 warranty detection range (ppm) 200
Linearity Full-scale ppm error, linear at 0-20ppm 1~10
Overload ppm for stable response to gas pulses 1000


V. Electrochemical ammonia gas sensor (NH3 sensor) NH3-A1Lifetime:

Zero drift ppm change per year in laboratory air <2
Sensitivity drift Percentage change per year in laboratory air <3
Operating life Time for output to drop to 80% of original signal (months) (warranty 12 months) >24


VI. Electrochemical ammonia gas sensor (NH3 sensor) NH3-A1Cross sensitivity:

H2S Percentage sensitivity to 20ppm H2S <300
NO2 Percentage sensitivity to 20ppm NO2 <-300
Cl2 Percentage sensitivity to 10ppm Cl2 <-300
NO Percentage sensitivity to 50ppm NO nd
SO2 Percentage sensitivity to 20ppm SO2 nd
CO Percentage sensitivity to 400ppm CO <20
H2 Percentage sensitivity to 400ppm H2 <15
C2H4 Percentage sensitivity to 400ppm C2H4 nd
CO2 Percentage sensitivity to 5% CO2 nd


VII. Electrochemical ammonia gas sensor (NH3 sensor) NH3-A1Key parameters:

Temperature range ℃ -30~50
Pressure range Kpa 80~120
Humidity range %rh 15~90
Storage life Sealed storage life at 3-20℃ (months) 6
Load resistor Ω (recommended) 10~47
Bias voltage mV 200
Weight grams <6