Russian Comeco Temperature and Humidity Sensor Temperature and Humidity Probe RHA-e
Russian Comeco Temperature and Humidity Sensor Temperature and Humidity Probe

Russian Comeco Temperature and Humidity Sensor Temperature and Humidity Probe - RHA-e

Low Cost
Voltage Output Signal
Built-in Temperature Sensor

Model: RHA-e

Product Introduction

I. Russian Comeco Temperature and Humidity Sensor Temperature and Humidity Probe RHA-eDescription:

RHA utilizes a thin-film sensor whose capacitance changes proportionally with the relative humidity of the medium, measuring the relative humidity of air and non-corrosive gases under normal ambient pressure and converting it into a standard voltage signal. This probe is based on the RHT sensor, but its electronics are housed in a cylindrical body, making it particularly suitable for rapid measurements when combined with handheld humidity measuring devices with programmable or scalable inputs. Additionally, a platinum temperature sensor can be installed in the probe for simultaneous measurement of the medium temperature.

The RHA probe can be conveniently connected to the H5800 meter via its flexible cable with a micro connector, forming a lightweight, versatile, and widely applicable handheld relative humidity measuring device.


II. Features of Russian Comeco Temperature and Humidity Sensor Temperature and Humidity Probe RHA-e:

RH/T probe for handheld meter RHA

Low cost
Voltage output signal
Built-in Temperature Sensor
Can be used with H5800 handheld meter or standalone
Compact structure, easy to use
Quick connection


III. Parameters of Russian Comeco Temperature and Humidity Sensor Temperature and Humidity Probe RHA-e:

Input
Humidity
Capacitive sensor, 0 - 100% RH
Temperature (optional)
Pt100 or Pt1000 (w=1.385)  (1) , -10 ~ 50°C
Accuracy
Class 'B'
Output
Output voltage
min. 0...max. 100 mV DC
Linearly proportional
Measured value
Accuracy
Measurement error
2.5% from span
Non-linearity
within measurement error
Temperature drift
0.1% from span for 1 °C
Power supply
Supply voltage
DC from the handheld meter
Admissible variations
20 mVp-p at 50 Hz
Operating conditions
Ambient temperature
-10 ~ 50°C
Ambient humidity
0 - 85 %RH, non-condensing
Design and materials
Case material
stainless steel
Sintered filter (option)
stainless steel, 75 μm
Wiring
1-5 m PVC or silicone cable
w/ 4-pin M8 connector type 'C3'
Dimensions
ø16x min. 120 mm (w/o cable and filter)
Weight
30 g (w/o cable and filter)
Protection class
IP54 (except sensor)

RHA Humidity Probe Ordering Code  RHA - G8 - #1.#2
Code
Feature or option
Code values
G8
Cable length 'k' [m] and type
1PV…5PV - PVC, 1SL…5SL - silicone
#1 Built-in temperature sensor
X - none, D - Pt100, G - Pt1000
#2 Sintered filter
X - none, S - sintered filter mounted