Product Introduction
I. Description of Fiber Optic Pressure Sensor FOP-MIV:
Fiber Optic Pressure SensorFOP-MIVDesigned for medical original equipment manufacturer devices. Its exceptional measurement performance is ideal for pressure monitoring in vascular, uterine, or cranial cavities. The large measurement range and small size (550um diameter) design make the FOP-MIV pressure sensor an ideal choice for instruments mounted inside catheters. The pressure sensor is immune to electromagnetic and radio frequency interference, and can achieve highly accurate measurements even in strong electromagnetic/RF environments such as electrosurgical knives or MRI interference.
II. Application Products of Fiber Optic Pressure Sensor FOP-MIV
FOP-MIV Sensor
FPI-HR Module
EVOLUTION Base
III. Main Features of Fiber Optic Pressure Sensor FOP-MIV
High Precision
Completely Immune to EM/RF/MW Interference
Ultra-Miniature for Real-Time Pressure Measurement
Rugged Sensor
IV. Parameters of Fiber Optic Pressure Sensor FOP-MIV
| Pressure Range Selection | R1 | R2 |
| Pressure Measurement Range | −300 mmHg ~ 300mmHg | −300 mmHg ~ 7500mmHg |
| Thermal Effect Sensitivity | −0.05% / °C | 0.15% / °C |
| Thermal Effect Zero | −0.4 mmHg / °C | 3 mmHg /°C |
| Withstand Pressure | >4000 mmHg (0.53 MPa) | 22 500 mmHg (3 MPa) |
| Accuracy | 1.5% FS | 0.1% |
| 分辨率 | <0.3 mmHg (40 Pa) | 2.6 mmHg (0.34 kPa) |
| Sampling Rate | 250 Hz per module | U50 Hz per module |
| Power consumption | 5 W | 5 W |
| Analog Output (Optional) | 0 to 5V or 4–20 mA / 16-bit resolution | 0 to 5V or 4–20 mA / 16-bit resolution |
| 工作温度 | 10ºC ~50ºC | 10ºC~50ºC |
| Storage temperature | −30ºC ~ 80ºC | −30ºC ~ 80ºC |
| Connector | SCAI, SCA (ST optional) | SCAI, SCA (ST optional) |
| Fiber Core Size |
62.5/125μm (50/125μm optional) | 62.5/125μm (50/125μm optional) |
| Number of Channels | 1 or 2 | 1 or 2 |
| Communication / Evolution Base | USB via EVO Base / TS 35 DIN Rail | USB via EVO Base / TS 35 DIN Rail |
| Communication/OEM |
RS-232 / RS-485 | RS-232 / RS-485 |
| LED Sensor Signal and Communication Diagnostics |
Yes | Yes |
1. Relative to atmospheric pressure
2. Or ±1 mmHg, whichever is greater
3. Or ±8 mmHg, whichever is greater
4. SCAI is an SCA connector with a smart chip that transmits calibration data to the signal conditioner module.
Laboratory
" Preclinical Research
" Animal Experiments
" Pharmacology
Medical
" Cardiology
" Neurology
" Anesthesiology
" Pulmonology
" Gastroenterology
" Urology
" Gynecology
" Ophthalmology
" Electrosurgery
" Hyperthermia
" Preclinical Trials
" MRI and Other RFI Environments
OEM Products
" Embedded Devices in Custom Medical Diagnostic and Therapeutic Instruments
" High Volume – Low Cost
" Proven high-yield fully automated production
Equipment and operation comply with standards of recognized medical institutions
Computerized Product Testing Production Line