Product Introduction
I. UV Detector - GUVx-T1xGC-I8LW5Features
- Installation size: PT1/4 "/12 mm
- Single supply voltage, 4~20mA current output
- Water environment (less than 10 bar)
II. Applications of UV Detector - GUVx-T1xGC-I8LW5
UV power measurement
UV lamp monitoring
III. Photoelectric Characteristics of UV Detector - GUVx-T1xGC-I8LW5
Supply voltage: DC 9~24V
Compensation current: 3.9~4.1mA, typical 4 mA
Spectral detection range:
GUVV-T11GC-I8LW5:230~395nm
GUVB-T12GC-I8LW5:220~320nm
GUVC-T11GC-I8LW5:220~280nm
Output current: 4~20 mA
Detection power range: 0~100㎽/㎠
Response time: 10ms