Product Introduction
Korean GENICOM UV Sensor GUVCL-T10GD Features:
AlGaN-based material
Schottky-type photodiode
Photovoltaic mode operation
Good solar blindness
Korean GENICOM UV SensorGUVCL-T10GD Applications:
Sterilization lamp monitoring
Korean GENICOM UV SensorGUVCL-T10GD Parameters:
Absolute Maximum Ratings
| Parameter |
Symbol |
Min |
Max |
Unit |
Test Condition |
| Storage Temperature |
Tst |
-40 |
90 |
℃ |
|
| Operating Temperature |
Top |
-30 |
85 |
℃ |
|
| Reverse Voltage |
Vr, max. |
|
3 |
v |
|
| Forward Voltage |
If,max. |
|
1 |
㎃ |
|
| Light Source Power Range |
Popt |
0.1µ |
100m |
W/㎠ |
UVC LED |
| Soldering Temperature |
Tsol |
260 |
|
℃ |
Within 10 seconds |
Characteristics (@ 25℃)
| |
Symbol |
Min |
typ |
Max |
Unit |
Test Condition |
| Dark Current |
Id |
|
|
1 |
㎁ |
Vr = 0.1 V |
| Photocurrent |
Iph |
111 |
123 |
135 |
㎁ |
UVC LED, 1㎽/㎠ |
| Temperature Coefficient
|
Itc |
|
0.1 |
|
%/℃
|
UVC LED |
| Responsivity
|
R |
|
0.1 |
|
A/W
|
λ = 280㎚, Vr = 0 V |
| Spectral Detection Range |
λ
|
230 |
|
320 |
㎚
|
10% of R |
| Active Area |
|
|
0.076 |
|
㎟ |
|