Sterilization lamp monitoring


Korean GENICOM UV SensorGUVCL-T10GD Parameters:


Absolute Maximum Ratings

Parameter

Symbol

Min

Max

Unit

Test Condition

Storage Temperature

Tst

-40

90

℃

 

Operating Temperature

Top

-30

85

℃

 

Reverse Voltage

Vr, max.

 

3

v

 

Forward Voltage

If,max.

 

1

㎃

 

Light Source Power Range

Popt

0.1µ

100m

W/㎠

UVC LED

Soldering Temperature

Tsol

260

 

℃

Within 10 seconds

 


Characteristics (@ 25℃)


Symbol

Min

typ

Max

Unit

Test Condition

Dark Current

Id

 

 

1

㎁

Vr = 0.1 V

Photocurrent

Iph

111

123

135

㎁

UVC LED, 1㎽/㎠

Temperature Coefficient

 

Itc

 

0.1

 

%/℃

 

UVC LED

Responsivity

 

R

 

0.1

 

A/W

 

λ = 280㎚, Vr = 0 V

Spectral Detection Range

λ

 

230

 

320

㎚

 

10% of R

Active Area

 

 

0.076

 

㎟