Indoor Air Quality Tester 2211
Indoor Air Quality Tester

Indoor Air Quality Tester - 2211

- High-precision sensors ensure stable and accurate test data
- Can be connected to a computer for continuous monitoring or remote monitoring
- Enables comprehensive monitoring and trend analysis
- Tests and stores multiple parameters simultaneously, such as CO, CO2, T, RH%, etc., to monitor indoor air quality
- Can directly calculate dew point, wet bulb temperature, absolute humidity, moisture content, and outdoor air percentage
- Has powerful data storage and processing functions, capable of calculating average, maximum, minimum values, etc.

Product Model: 2211

Product Introduction

Indoor Air Quality Tester 2211 Product Overview:

- High-precision sensors ensure stable and accurate test data
- Can be connected to a computer for continuous monitoring or remote monitoring
- Enables comprehensive monitoring and trend analysis
- Tests and stores multiple parameters simultaneously, such as CO, CO2, T, RH%, etc., to monitor indoor air quality
- Can directly calculate dew point, wet bulb temperature, absolute humidity, moisture content, and outdoor air percentage
- Has powerful data storage and processing functions, capable of calculating average, maximum, minimum values, etc.


Indoor Air Quality Tester 2211Product Features:

Name

Indoor Air Quality Tester

Model

2211

Test Object

Indoor Air Quality

CO

Test Range

0~500PPM

Test Accuracy

±3% of reading or ±3PPM, whichever is greater

Resolution

0.1PPM(0~99.9PPM):1PPM(100~500PPM)

CO2

Test Range

0~5000PPM

Test Accuracy

±3% of reading

Resolution

1PPM

Temperature

Test Range

-20~60℃ (-4~140oF)

Test Accuracy

±0.5℃ (±1oF)

Resolution

0.1℃ (0.1oF)

Relative Humidity

Test Range

2~98%RH

Test Accuracy

2~80%RH:±2%RH 80~98%RH ±3%RH

Resolution

0.1%RH

Functions

Normal Mode

Normal testing (without storing or calculating data) CO, CO2, temperature, relative humidity, dew point, wet bulb temperature, absolute humidity, humidity ratio, etc.

Calculation Mode

Stores data, can calculate maximum, minimum, average values, etc.

%OA Mode

Indoor/outdoor ventilation efficiency test (calculated from temperature and CO2 values)

Data Output Mode

Calculates stored data and outputs to computer or printer

Calibration Mode

Calibrates CO and CO2

Output

Digital Output

RS232C (Baud rate: 4800, 9600, 19200, 38400 bps)

Analog Output DC: 0~1V (select one from CO, CO2, temperature, relative humidity)

Power Supply

DC: 6 AA batteries (alkaline or Ni-Cd rechargeable) AC: 100~240V (50/60Hz) *AC adapter optional

Battery Life

Approximately 10 hours (at 25°C, without RS232C connection, alkaline batteries)

Operating Environment

Main Unit

5~40℃

Probe

-20~60℃

Storage Environment

-20~60℃

Standard Configuration

Carrying case, user manual, 6 AA batteries, probe holder, calibration cap, connecting tube, test software, RS232C communication cable

Optional Accessories

Spare probe, analog output, flow control valve, AC adapter, printer, zero calibration gas, span calibration gas (for CO/CO2)