Home chevron_right Sensors chevron_right Water Quality Sensor 
Online Chlorine Water Quality Probe AMT-YL300 for Hotel Swimming Pools
Online Chlorine Water Quality Probe for Hotel Swimming Pools
Online Chlorine Water Quality Probe for Hotel Swimming Pools

Online Chlorine Water Quality Probe for Hotel Swimming Pools - AMT-YL300

Built-in chip simultaneously collects waterpH and temperature are automatically compensated through algorithms, eliminating interference from pH and temperature on residual chlorine forms, converting to the true residual chlorine concentration, and outputting digital signals

Product Model: AMT-YL300

Product Introduction

Online Chlorine Water Quality Probe for Hotel Swimming Pools

1. Measurement Principle

Mainstream is three-electrode potentiostatic (constant voltage) membrane electrochemical method (polarographic membrane method):

The sensor consists of a working electrode, counter electrode, and reference electrode, with a selective permeable membrane at the front;

Hypochlorous acid in the water sample (HOCl, free residual chlorine effective component) passes through the membrane, undergoes redox reaction on the working electrode surface, generating a weak diffusion current;

Current magnitude is linearly related to residual chlorine concentration;

Built-in chip simultaneously collects water pH, temperature, automatically compensated through algorithms, eliminating pH, temperature interference on residual chlorine forms, calculates true residual chlorine concentration, outputs digital signal.

A few optical smart residual chlorine sensors adopt DPD Spectrophotometric color development principle, higher accuracy, but requires periodic reagent replenishment and higher maintenance costs.

2. Structural Composition

Sensing probe: platinum / Gold working electrode, silver/silver chloride reference electrode, breathable membrane cap;

Built-in sensing unit: integrated temperature electrode, many models integrate pH Electrode;

Signal and processing module: embedded MCU, signal amplification, filtering, calibration algorithm;

Communication circuit:RS485 Modbus-RTU, some also support 4-20mA Analog output;

Housing:316L Stainless Steel / ABS,IP68 Waterproof, supports pipeline flow cell installation or immersion installation.

Online Chlorine Water Quality Probe for Hotel Swimming Pools

3. Core Features (Smart comparison with traditional analog residual chlorine electrodes)

Digital signal output:RS485 Modbus, strong anti-interference, long-distance transmission, supports multi-sensor bus networking;

Automatic compensation:pH + Dual temperature compensation, solving the pain point of residual chlorine measurement being greatly affected by pH and water temperature;

Local storage and self-diagnosis: built-in calibration records, fault self-check, can alert for membrane aging and electrode contamination;

Reagent-free continuous monitoring: electrochemical membrane type requires no chemical reagents, suitable for long-term online operation;

Installation flexibility: pipeline flow cell, immersion, tank installation; some with flow stabilization structure to reduce water flow velocity interference;

Easy maintenance: membrane cap and electrode can be replaced separately, calibration is simple.

4. Typical Technical Parameters (General Reference)

Measurement target: free residual chlorine (total chlorine optional)

Range:0~5mg/L、0~10mg/L、0~20mg/L Optional

Resolution:0.01mg/L

Accuracy:±5% FS, low concentration range up to ±0.05mg/L

Response time T90:20~60s

Temperature measurement:0~50℃, automatic temperature compensation

Communication:RS485 Modbus RTU

Protection rating:IP68

Power supply:DC12~24V

Online Chlorine Water Quality Probe for Hotel Swimming Pools

5. Application scenarios

Water treatment plant: online residual chlorine monitoring of finished water and filtered water;

Secondary water supply / Pipe network monitoring: water quality monitoring in residential pump rooms and pipe network endpoints;

Swimming pool and hot spring water: real-time monitoring of pool water disinfection residual chlorine;

Industrial water treatment: circulating cooling water, reclaimed water reuse, reverse osmosis pretreatment;

Sewage disinfection process: sodium hypochlorite / Monitoring of tail water after chlorine dioxide disinfection.

6. Purpose and Value

Real-time monitoring of residual chlorine to prevent microbial growth due to too-low levels or disinfection byproducts from too-high levels;

Linked with chlorine dosing pump to form an automatic chlorination closed-loop control system, reducing labor and stabilizing water quality;

Data uploaded to cloud platform, supports historical record query and over-limit alarms, meeting water utility environmental online supervision;

Replace manual DPD Colorimetric spot checks, solving the shortcomings of manual sampling lag and inability to monitor continuously.

7. Maintenance Points

Regularly clean the probe membrane surface to prevent algae, sludge, and scale adhesion;

Regularly calibrate with standard solution (generally 1~3 monthly);

The permeable membrane has a service life, generally 6~12 Replace membrane cap every month;

Avoid high turbidity and heavily oil-contaminated water bodies directly impacting the electrode membrane.

If you need, I can help you organize a smart residual chlorine sensor selection guide or a concise product manual.

 

Main Application Areas

  • Swimming Pools — Continuous monitoring of residual chlorine in swimming pools to ensure safe disinfection levels and water quality compliance.
  • Drinking Water Treatment — Real-time monitoring of free chlorine in drinking water distribution systems to maintain effective disinfection and public health safety.
  • Wastewater Treatment — Monitoring residual chlorine in effluent to ensure proper disinfection before discharge and to meet environmental regulations.
  • Cooling Water Systems — Control of chlorine dosage in industrial cooling towers to prevent microbial growth and biofouling.

Keywords:residual chlorine sensor, online chlorine analyzer, water quality sensor, swimming pool chlorine monitor, free chlorine probe, digital chlorine sensor, smart water quality sensor, AMT-YL300