4. American NovaLynx 210 210-41342
1. American NovaLynx 210

184. American NovaLynx 210 - 210-41342

185. Temperature (41342, 41382)
186. Calibrated measurement range:
187. -50 ~50 °C (suffix C)
188. -50 ~150 °F (suffix F)
189. Response time: 10 seconds (without filter)
190. Accuracy at 23 °C: ± 0.3 °C
191. Sensor type: Platinum resistance temperature sensor
192. Output signal: V option: 0-1 Vdc
193. L option: 4-20 mA
194. Relative Humidity (41382)
195. Measurement range: 0-100% RH
196. Accuracy at 20-25 °C: ± 1% RH
197. Stability: better than ± 1% RH per year
198. Response time: 10 seconds (without filter)
199. Sensor type: Rotronic Hygromer™
192. Output signal: V option: 0-1 Vdc
200. L option: 4-20 mA

201. Product Model: 210-41342

204. Product Introduction

205. 210-41342 Temperature Probe Description

206. Model207. 210-41342 Temperature Probe208. is a 1000 ohm platinum resistance temperature sensor, installed in a stainless steel protective sheath. The sensing element is firmly installed in the junction box. For special applications, the temperature probe provides different output options. For high noise, industrial settings, or long cables, the 4-20mA current output is useful. Option 0-1 Vdc provides a calibrated voltage output signal. Low power circuitry makes it suitable for field research and remote data logging applications.

209. 225-41382 Relative Humidity & Temperature Probe210. Combines a high-precision humidity sensor and a 1000 ohm platinum resistance temperature sensor. Suitable for 0-1 Vdc or 4-20 mA output, the sensor is installed in a universal junction box.

The211. 225-46203 Temperature Tracker212. is a versatile temperature, dew point, and relative humidity indicator. The measured values are displayed on the front panel in large luminous digits. Luminous digits: temperature on the left, relative humidity on the right. Saves max and min and can be viewed at any time. Used with213. 225-41382LC Humidity & Temperature Probe214. in conjunction.


215. 210-41342 Temperature Probe216. Technical Specifications:
217. Temperature (41342, 41382)
218. Calibrated measurement range:
219. -50 ~50 °C (suffix C)
220. -50 ~150 °F (suffix F)
221. Response time: 10 seconds (without filter)
222. Accuracy at 23 °C: ± 0.3 °C
223. Sensor type: Platinum resistance temperature sensor
224. Output signal: V option: 0-1 Vdc
225. L option: 4-20 mA
226. Relative Humidity (41382)
227. Measurement range: 0-100% RH
228. Accuracy at 20-25 °C: ± 1% RH
229. Stability: better than ± 1% RH per year
230. Response time: 10 seconds (without filter)
231. Sensor type: Rotronic Hygromer™
224. Output signal: V option: 0-1 Vdc
232. L option: 4-20 mA