Home chevron_right Sensors chevron_right Gas Sensor chevron_right Freon sensor 
Japan Figaro Freon sensor TGS2630 for detecting refrigerant gas
Japanese Figaro Freon sensor for detecting refrigerant gas

Japan figaro Freon sensor for detecting refrigerant gas - TGS2630

Features:
High sensitivity to non-flammable refrigerants
Greatly improved selectivity
Simple application circuit
Low Power Consumption

Product Model: TGS2630

Product Introduction

1. Description of Japan Figaro Freon sensor TGS2630:

The sensing element consists of an integrated heater and a tin oxide (SnO2) semiconductor on an alumina substrate. When the gas to be detected is present in the air, the higher the concentration of the gas, the higher the conductivity of the sensor. Using a simple circuit, the change in conductivity can be converted into a signal output corresponding to the gas concentration.

Freon sensorTGS2630 is widely used to detect refrigerants R-404a and R-410a commonly used in air conditioners and refrigeration equipment, and also has high sensitivity to non-flammable refrigerant gases R-32 and R-1234yf that help prevent global warming. Due to the built-in filter layer, its sensitivity to volatile alcohols (common interfering gases in living environments) is very low, demonstrating high selectivity for non-flammable refrigerants. Since the sensing element is very small, the heater current of TGS2630 is only 56mA, and the housing adopts a standard TO-5 metal package.


2. Features of Japan Figaro Freon sensor TGS2630:

High sensitivity to non-flammable refrigerants
Greatly improved selectivity
Simple application circuit
Low Power Consumption


3. Applications of Japan Figaro Freon sensor TGS2630:
Leak detection of refrigerants in air conditioning and refrigeration systems


4. Parameters of Japan Figaro Freon sensor TGS2630:

Product name

Freon sensor

Model

TGS2630

Detection principle

Metal oxide semiconductor type

Standard Package

TO-5 metal

Target gas

Refrigerant gas

Detection range

1000 ~ 10000ppm



Standard circuit conditions


Heater voltage

V H

5.0±0.2V AC/DC


Loop Voltage

V C

5.0±0.2V DC


Ps≤15mW


Load Resistance

R L

Variable

0.45kΩ min




Standard test conditions

Electrical characteristics under

Heater resistance

R H

Approximately 59Ω at room temperature (typical)


Heater current

I H

56±5mA


Sensor resistance

R S

0.46 ~ 10kΩ
In 5000ppm R-32


Sensitivity (change rate of Rs)

0.2~0.7
(R-32)

Rs (9000ppm )
Rs (3000ppm )




Standard test conditions


Test gas conditions

R-32 in air
20±2˚C, 65±5%R.H.



Circuit conditions

Vc = 5.0±0.01V DC
V H = 5.0±0.05V DC


Preheating Time

7 days





5. Pre-calibration module of Japan Figaro Freon sensor TGS2630:


Japan Figaro refrigerant gas R-32<font color='red'>pre-calibration module</font>

Japan Figaro refrigerant gas R-32Pre-calibration module - FCM2630

FCM2630-C00 is a pre-calibrated module equipped to detect the non-flammable refrigerant gas R-32. It is compact and can be easily integrated into various devices.