Product Introduction
-
1. Hydrogen Sulfide Sensor (H2S Sensor) ME3-H2S Product Description
-
The ME3-H2S sensor is a constant potential electrolytic H2S sensor. H2S and O2 undergo corresponding oxidation-reduction reactions at the working electrode and counter electrode, releasing charge to form a current. The current magnitude is proportional to the H2S concentration, and the H2S concentration can be determined by measuring the current.
-
- 2. Hydrogen Sulfide Sensor (H2S Sensor) ME3-H2SFeatures
-
Low power consumption, high precision, high sensitivity, wide linear range, strong anti-interference capability, excellent repeatability and stability.
-
-
3. Hydrogen Sulfide Sensor (H2S Sensor) ME3-H2S Main Applications
-
Widely suitable for hydrogen sulfide detection in industry, underground mines, and environmental protection.
-
- 4. Hydrogen Sulfide Sensor (H2S Sensor) ME3-H2S Technical Specifications
| Model |
ME3-H2S |
Remarks |
| Detection Range (ppm) |
0-100, max range 5000 |
|
| Sensitivity (µA/ppm) |
(0.8±0.15)µA/ppm |
|
| Repeatability |
Output signal ±2% |
|
| Response Time (t90) s |
≤30s |
|
| Signal Attenuation |
≤2% |
/month |
| Zero Drift (ppm) |
0.2ppm |
Clean air |
| Temperature Range (°C) |
-20~+50 |
|
| Temperature Drift (ppm) |
≤0.5 |
20~50℃ |
| Humidity Range |
≤95%RH |
|
| Pressure Range (kPa) |
90~110 |
|
| Storage Temperature (°C) |
0~20 |
Recommended |
| Storage Period (months) |
6 |
|
| Expected Service Life (months) |
>24 |
|
| Detection Concentration (ppm) |
300 |
|
| Model |
ME3-H2S |
Remarks |
| Detection Range (ppm) |
0-200 |