German Passerro Online Breakdown Voltage Sensor Insulating Oil Test Device - BDVB TrafoStick TS4x
The BDVB TrafoStick TS4x sensor is specially developed for permanent on-site use in transformers, specifically for continuous real-time measurement of breakdown voltage, moisture content, and temperature of mineral oil-based transformer oil.
Product Introduction
German PasserroOnline Breakdown Voltage SensorInsulating Oil Test Device BDVB TrafoStick TS4x Description:
The main measuring module is housed in a robust metal enclosure. The measuring chamber is made of anodized aluminum. Through perforations in the measuring chamber, the internal sensor can be filled with insulating oil. The BDVB sensor is equipped with a Parker RI1EDX3/471 fitting, allowing the device to be screwed into the target position. The sensor can be installed in any orientation, but it must be ensured that oil can flow freely through the measuring chamber. The cable connection is located at the top of the sensor.
The connection between the TrafoStick and the control unit is established using the provided cable via a WEiPU ST1210 / S9 connector. The sensor is connected to a computer, router, modem, or similar device using the provided TCP-IP cable.
German Passerro Online Breakdown Voltage Sensor Insulating Oil Test Device BDVB TrafoStick TS4x Applications:
The BDVB TrafoStick TS4x sensor is specially developed for permanent on-site use in transformers, specifically for continuous real-time measurement of breakdown voltage, moisture content, and temperature of mineral oil-based transformer oil.
German Passerro Online Breakdown Voltage Sensor Insulating Oil Test Device BDVB TrafoStick TS4x Parameters:
| Measurement Parameters |
|
| Breakdown Voltage (BDV) |
10kV ~ 120kV ( ± 2.5%) |
| Moisture Content (WC) |
2 ppm ~ 80 ppm (± 2%) |
| Temperature |
-40 ~ 120 ± 0,2°C |
| Measurement Interval |
max. 0.1s |
| Operating Environment |
|
| Ambient Temperature |
-20°C ~ 70°C |
| Oil Temperature Range |
-20°C ~ 85°C |
| Operating Pressure |
Up to 3 bar |
| Inputs and Outputs |
|
| Power Supplies
|
4.5V ~ 7.5V (5.0VRecommended Value)
|
| Output |
Digital Protocol |
| Interface |
MODBUS TCP/IP |
| Internal Data Logging Capability |
Dynamic Latch Buffer Buffer Chain (64-256-1024) |
| General Information |
|
| Cable |
Standard MODBUS (Variable Length) |
| Housing Material |
EN-AW-6063 |
| Mechanical Connection |
Parker RI1EDX3/471 |
| Measuring Area Material |
EN-AW-7075 |
| Assembly Housing Category |
IP68 |
| Control Software (Windows 7and above) |
Ver. 2.0 |
| Absolute Maximum Ratings |
|
| zuiMaximum Operating Voltage |
9.0V |
| Operating Temperature |
-40°C ~ 100°C |
| zuiMaximum Pressure |
5bar |
| Storage Temperature (without MODBUScable) |
-65°C ~ 150°C |