US SENIX Corrosion-Resistant Liquid Level Sensor - ToughSonic CHEM 10
The ToughSonic CHEM 10 sensor is ruggedly built:
Chemical-resistant PVDF housing.
Sealed epoxy potting, IP68 immersion rating, and impact resistance.
Rugged piezoelectric ultrasonic transducer, potted in place.
Robust, tough solid-state internal electronics.
UV-resistant, 6.5-foot (2-meter) potted 9-wire cable standard.
Product Introduction
1. US SENIX Chemical-Resistant Liquid Level Sensor ToughSonic CHEM 10 Description:
The ToughSonic CHEM 10 is suitable for applications with corrosive liquids or gases, but it is also a good choice for benign environments. It is the shorter range model with a 10-foot (3-meter) range in the ToughSonic CHEM sensor series.
The ToughSonic CHEM 10 is sealed in a PVDF (Kynar) housing. Fully submersible, chemical-resistant, and impact-resistant. It has a potted 9-wire cable that can connect up to five simultaneous analog and/or switch outputs as well as a serial interface. It is fully configurable with SenixVIEW configuration and analysis software.
2. Chemical-Resistant Liquid Level Sensor ToughSonic CHEM 10 Sensor Models:
Models are distinguished by data connection type, typically used with SenixVIEW software. All models have the same analog and switch output functions and features.
LVL-100-232
Modbus RS-232 serial data interface
LVL-100-485
Modbus RS-485 serial data interface
U10-CHEM-BLE
Modbus RS-485 serial data interface plus AirWire wireless interface.
Sensor Customization
Custom SenixVIEW configurations can be designed and pre-loaded for your unique application.
Optional cable types, lengths, and connectors.
Metric or BSP threads available.
3. US SENIX Chemical-Resistant Liquid Level Sensor ToughSonic CHEM 10 Features:
The ToughSonic CHEM 10 sensor is ruggedly built:
Chemical-resistant PVDF housing.
Sealed epoxy potting, IP68 immersion rating, and impact resistance.
Rugged piezoelectric ultrasonic transducer, potted in place.
Robust, tough solid-state internal electronics.
UV-resistant, 6.5-foot (2-meter) potted 9-wire cable standard.
4. US SENIX Chemical-Resistant Liquid Level Sensor ToughSonic CHEM 10 Specifications:
| Range |
10 feet (3 meters) |
| Recommended Range |
4 inches - 80 inches (102 mm - 2 meters) |
| Temperature |
-40° to 158°F (-40° to 70°C) |
| Humidity |
0 to 100% operating |
| Protection |
NEMA-4X,NEMA-6P,IP68 |
| Sensors |
Rugged piezoelectric |
| Compensation |
TemperatureCompensated |
| Resolution |
Digital: 0.0034 inches (0.086 mm) Analog: 4099 steps (0-10 VDC), 3279 steps (4-20 mA) |
| Repeatability |
Nominal 0.2% of range at constant temperature; affected by target, distance, environment |
| Update Rate |
5 Hz (100 ms), adjustable via SenixVIEW; affected by SenixVIEW filters |
5.Chemical-Resistant Liquid Level Sensor ToughSonic CHEM 10Outputs
| Wireless BLE |
Link available for AirWire models |
| Voltage Output |
0-10, 0-5 VDC or SenixVIEW custom; 10 mA |
| Current Loop #1 |
Sourcing 4-20 mA or SenixVIEW custom, loop 450 Ω |
| Current Loop #2 |
Sinking 4-20 mA or SenixVIEW custom, loop 450 Ω |
| Sinking Switch |
150 mA @ 40 VDC, settable setpoint and polarity, fault indication |
| Sourcing Switch |
150 mA @ input voltage, settable setpoint and polarity, fault indication |
| RS-232,RS-485 |
Modbus protocol, 9600-115200 baud rate (optional), 8 data bits, 1 stop, no parity |
| SYNC Function |
Allows up to 32 sensors to operate in close proximity without interference |
6.Chemical-Resistant Liquid Level Sensor ToughSonic CHEM 10Mechanical
| Mounting |
1.5-inch NPT / BSP common thread. 1-inch NPT face thread |
| Connection Cable |
6.5 feet (2 meters) |
| Total Weight |
22.6 oz (0.64 kg) |