Product Model: SKA-NE-301

Product Introduction

I. Product Overview of Central Air Conditioning Room Refrigerant Leak Alarm

Freon gas alarm (refrigerant gas detection alarm system), composed ofGas alarm controller + Freon gas detectorComposed of, belonging to industrial fixed gas detection equipment. Specifically designed for real-time concentration monitoring of refrigerant leaks such as R22, R32, R134a, R410A, widely used in refrigeration machine rooms, cold storage, central air conditioning machine rooms, refrigerant filling workshops, pharmaceutical cold chain warehouses and other scenarios. The equipment performs 24-hour online detection of Freon concentration in the air. When the leakage concentration reaches the preset alarm threshold, it immediately triggers sound and light alarms and can link with fans, solenoid valves and other equipment to promptly eliminate leakage hazards, protect on-site personnel safety, and meet safety supervision and cold storage safety acceptance specifications.

II. Product Introduction of Central Air Conditioning Room Refrigerant Leak Alarm

Freon refrigerant is colorless and odorless, difficult to detect after leakage; refrigerants such as R32 are flammable, and large accumulation can easily cause explosion and suffocation, while also causing refrigerant loss and environmental pollution. This Freon alarm system uses dedicated infrared/semiconductor sensors, with detectors installed in areas prone to leakage accumulation, collecting Freon concentration signals in real time and transmitting them via wired connection to the alarm host. The host displays on-site concentration values in real time, with sound and light prompts when exceeding limits; supports RS485 and 4-20mA signal output, can connect to PLC, DCS, and cloud platforms for remote monitoring. The whole machine has an explosion-proof design, suitable for humid cold storage and interference-heavy industrial environments in machine rooms. The complete system has full qualifications, can be used for project safety acceptance, and supports on-site installation and commissioning and solution customization.

III. Functional Features of Central Air Conditioning Room Refrigerant Leak Alarm

  1. Dedicated refrigerant sensor: Sensitive response to R22/R32/R134a/R410A Freon, strong anti-interference, rapid detection of trace leaks.
  2. Real-time concentration display: Alarm host + detector optional display, intuitive viewing of on-site Freon real-time concentration.
  3. Two-level alarm function: Low alarm and high alarm dual-threshold settings, sound and light alarm when exceeding limits, reminding on-site personnel to handle.
  4. Linkage control outputOptional functions
  5. Multiple signal transmission: Supports 4-20mA analog and RS485 bus signals, can connect to industrial control systems and cloud platforms.
  6. Explosion-proof protective housing: Detector explosion-proof housing, suitable for explosion-proof areas such as refrigerant filling rooms, dustproof and moisture-proof.
  7. Fault self-check prompt: The system automatically monitors sensor disconnection and faults, and fault alarms remind operation and maintenance personnel for inspection and repair.
  8. Multi-point centralized monitoring: One alarm host can connect multiple detectors, achieving centralized monitoring of multiple points in multiple machine rooms.
  9. Data storage and traceability: The host can store alarm records and concentration history data, facilitating safety inspection traceability.
  10. Easy installation and maintenance: Split structure, host and detector installed separately; sensor can be replaced individually, convenient calibration.
  11. IoT remote version optional: 4G/WiFi wireless transmission, remote viewing of concentration and receiving alarm push notifications via mobile phone/computer.

IV. Technical Parameters of Central Air Conditioning Room Refrigerant Leak Alarm

Table

Item Parameter specifications
Detection gas Freon (R22, R32, R134a, R410A and other refrigerants, selected according to needs)
Detection principle Infrared sensor / semiconductor sensor (selected according to refrigerant type)
Measurement range 0~1000ppm / 0~5000ppm (range customizable)
分辨率 1ppm
Detection method Diffusion sampling
Alarm settings Level 1 low alarm, Level 2 high alarm, thresholds customizable
Response time ≤30s
信号输出 4-20mA, RS485 (Modbus), relay passive contacts
Explosion-proof grade Ex d IIC T6 Gb (detector)
防护等级 IP65
Working power supply Detector: DC24V; Alarm host: AC220V
工作温度 -20℃~+50℃
Working humidity 10% RH~95% RH, no condensation
Transmission distance Bus type max 1000m; 4-20mA max 500m
Alarm method Host + detector sound and light alarm (red warning light + buzzer)
安装方式 Wall-mounted installation
Host capacity Can connect 1~64 detectors (host model optional)
: Relay switch quantity output, automatic linkage of exhaust fans and refrigerant shut-off solenoid valves when exceeding limits. 4G wireless transmission, cloud platform, data storage, local printing

Main Application Areas

  • Central Air Conditioning Rooms — Monitors refrigerant leaks in central AC plant rooms to ensure occupant safety and system integrity.
  • HVAC Systems — Detects refrigerant leaks in heating, ventilation, and air conditioning systems to prevent efficiency loss.
  • Industrial Refrigeration — Used in industrial refrigeration units to provide early leak warnings and avoid environmental hazards.
  • Commercial Buildings — Installed in commercial buildings to protect HVAC equipment and maintain indoor air quality.

Keywords:refrigerant leak alarm, central air conditioning leak detector, HVAC refrigerant sensor, industrial leak alarm, SKA-NE-301, refrigerant gas detector, AC room safety alarm, leak detection system