Cascade multi-point inclinometer - RTS
Acceleration measurement:
- Measurement range: ±16g
- Measurement accuracy: ±0.2mg
- Resolution: ±0.05mg
Baud rate: default 38400, customizable
Operating temperature: -40℃ to +85℃ with temperature sensor output
Power supply: default 5V, customizable
Product Model: RTS
Product Introduction
The cascade multi-point inclinometer RTS (Rock Tilt Sensor) can be networked in multi-point series based on the RS485 bus. Each node includes a high-precision three-axis MEMS gravity acceleration and temperature sensor. It is compact in size, only 55x30x22mm; lightweight, only 50g; and low cost, priced at 1/3 of similar products on the market.
Can be arranged in multiple points and chain series around monitoring hazard points such as unstable rock masses, retaining walls, dangerous buildings, landslides, and power towers. It can be installed flexibly in horizontal, transverse, and vertical orientations, and is applied in geological disaster monitoring such as collapses and landslides, as well as safety monitoring fields like bridges and buildings.
Equipment installation:
2.1 Pole installation method
Step 1: Pour the concrete foundation base.
The concrete foundation base is 500mm×300mm×400mm in length×width×depth, with 300mm underground and
100mm. Use a level to ensure the 100mm exposed cement platform above ground is level. The concrete strength
The strength is C25 or above.
Step 2: Pre-embed the equipment pole.
The equipment pole is made of galvanized steel pipe with a diameter of no less than 50mm and a height of no less than 500mm, of which 300mm is underground,
200mm above ground.
Step 3: Pre-embed the warning sign pole.
The warning sign pole is made of galvanized steel pipe with a diameter of 50mm and a height of 1800mm, of which 300mm is underground and
1500mm。
Step 4: Equipment installation.
Install the flange on the equipment pole first, then fix the RTS onto the flange.
2.2 Hanging installation method
When deploying RTS for monitoring hazard points such as unstable rock collapses or retaining wall collapses, the hanging installation method is recommended.
Step 1: Install the mounting plate.
Secure the RTS mounting plate with no less than 3 expansion screws of φ6mm.
Step 2: Install the RTS.
Recommended Products