  • The ME4-Cl2 sensor is a constant potential electrolytic CL2 sensor. CL2 and O2 undergo corresponding reduction and oxidation reactions at the working electrode and counter electrode, releasing corresponding charges to form a current. The current magnitude is proportional to the gas concentration and follows Faraday's law. By measuring the current magnitude, the CL2 concentration can be determined.

  • Chlorine Gas Sensor (CL2 Sensor) ME4-Cl2Sensor Features

  • Low power consumption, high precision, high sensitivity, wide linear range, strong anti-interference capability, excellent repeatability and stability.

  • Chlorine Gas Sensor (CL2 Sensor) ME4-Cl2Main Applications

  • Widely suitable for chlorine gas detection in chemical, pharmaceutical, and environmental protection industries.

  • Chlorine Gas Sensor (CL2 Sensor) ME4-Cl2Technical Specifications

  • Item Parameter
    Detection Gas Chlorine (Cl2)
    Range 0-20ppm
    Measurement Limit 250ppm
    Sensitivity 1±0.25 uA/ppm
    Resolution 0.1ppm
    Response Time (T90) ≤60s
    Bias Voltage 0mV
    Load Resistance (Recommended) 10Ω
    Repeatability <2% of output value
    Stability (per month) <2﹪
    Output Linearity Linear
    Zero Drift (-20°C to 40°C) ≤0.2ppm
    Temperature Range -20℃-50℃
    Humidity Range 15%-90% RH, no condensation
    Pressure Range Standard atmospheric pressure ±10%
    Detection Life 2 years