Home chevron_right Sensors chevron_right Gas Sensors chevron_right Carbon Monoxide Sensors chevron_right Civil Carbon Monoxide Sensors 
Carbon Monoxide Sensor (CO Sensor) MQ-7
Carbon Monoxide Sensor (CO Sensor)

Carbon Monoxide Sensor (CO Sensor) - MQ-7

Good sensitivity to carbon monoxide gas
Long life, low cost
Simple drive circuit required

Product Model: MQ-7

Product Introduction

  • Carbon Monoxide Sensor (CO Sensor) MQ-7 Product Description

  • The gas sensing material used in the MQ-7 gas sensor is tin dioxide (SnO2) with low conductivity in clean air. It adopts a high-low temperature cycling detection method. At low temperature (1.5V heating), it detects carbon monoxide, and the sensor's conductivity increases with the concentration of carbon monoxide gas in the air. At high temperature (5.0V heating), it cleans the stray gases adsorbed at low temperature. A simple circuit can convert the change in conductivity into an output signal corresponding to the gas concentration.

    The MQ-7 gas sensor has high sensitivity to carbon monoxide and can detect various gases containing carbon monoxide. It is a low-cost sensor suitable for multiple applications.


  • Carbon Monoxide Sensor (CO Sensor) MQ-7Sensor Features

  • Good sensitivity to carbon monoxide gas

    Long life, low cost

    Simple drive circuit required


  • Carbon Monoxide Sensor (CO Sensor) MQ-7Main Applications

  • Household gas leak alarms

    Industrial carbon monoxide gas alarms

    Portable gas detectors


  • Carbon Monoxide Sensor (CO Sensor) MQ-7Technical Specifications

  • Product Model

    MQ-7

    Product Type

    Semiconductor gas sensing element

    Standard Package

    Plastic encapsulation

    Detection Gas

    Carbon monoxide

    Detection Concentration

    10-1000ppmCO

    Standard Circuit Conditions

    Loop Voltage

    Vc

    ≤10V  DC

    Heating Voltage

    VH

    5.0V±0.2V AC or DC (high)

    1.5V±0.1V AC or DC (low)

    Heating Time

    TL

    60±1S (high) 90±1S (low)

    Load Resistance

    RL

    Adjustable

    Element Characteristics under Standard Test Conditions

    Heating Resistance

    RH

    31Ω±3Ω (room temperature)

    Heating Power Consumption

    PH

    ≤350mW

    Surface Resistance of Sensitive Body

    Rs

    2KΩ-20KΩ(in100ppmCO)

    Sensitivity

    S

    Rs(in air)/Rs(100ppmCO)≥5

    Concentration Slope

    α

    ≤0.6(R300ppm/R100ppm CO)

    Standard Test Conditions

    Temperature, Humidity

    20℃±2℃;65%±5%RH

    , , , ,

    Standard Test Circuit

    Vc:5.0V±0.1V; VH(High): 5.0V±0.1V; VH(Low): 1.5V±0.1V

    Preheating Time

    No less than 48 hours