US AII Long-Life Electrochemical Oxygen Sensor O2 Sensor GPR-11-60
US AII Long-Life Electrochemical Oxygen Sensor O2 Sensor
US AII Long-Life Electrochemical Oxygen Sensor O2 Sensor

US AII Long-Life Electrochemical Oxygen Sensor O2 Sensor - GPR-11-60

Compact PCB mounting structure
Easy to install and replace
Good sealing performance of the structure
Long life

Model: GPR-11-60

Product Introduction

US AII Long-Life Electrochemical Oxygen Sensor O2 SensorGPR-11-60 Description:

GPR-11-60 is a reliable electrochemical oxygen sensor designed for accurate detection of oxygen content in the range of 0% to 100%. The sensor is designed with simplicity and long-term stability in mind, featuring a compact PCB mounting structure for easy installation and replacement. Its sealed structure ensures stable operation, and it also has excellent signal-to-noise ratio for precise measurement data. With its long service life and stable performance, this sensor is ideal for OEM manufacturers requiring oxygen detection in industrial or analytical fields.



US AII Long-Life Electrochemical Oxygen Sensor O2 SensorGPR-11-60 Features:

Measurement range: 0–100% oxygen concentration
Signal output (in air): 35–55µA 
Sensitivity:1.67-2.63 µA/% O2 
Response time (T90): 9 seconds
Operating humidity: non-condensing, 0–99% RH
Electrical connection: dual-ring PCB structure



US AII Long-Life Electrochemical Oxygen Sensor O2 SensorGPR-11-60 Parameters:

Oxygen sensor model

GPR-11-60

Measurement range

0-100%O2

Signal output(1)

35-60 µA

Response time90%

9 seconds

Full-scale accuracy (2)

+ 1%

Accuracy within operating range (3)

+ 5%

Signal drift percentage per month (2

< 1%

Linearity(2)

+ 1%

Humidity non-condensing

0-99% RH

Temperature coefficient

2.54%

Operating temperature

0-45° C

Operating pressure

Constant 5-30 PSIG

Flow rate

1-10 LPM

Expected life(1)

60 Months

Storage(4)

0-40° C

Warranty(5)

12 Months

Electrical connection

PCB dual-ring structure

Packaging

Packed in polyethylene bag

3" x 3" x 1.5" paper box


(1) In air @ 25° C and 1 atm. Expected life varies inversely with changes in O2 concentration, temperature, pressure.
(2) Under constant conditions. Calibrate as near sample conditions as possible. Calibrate with 95-100% oxygen for measurements > 40% oxygen.
(3) Once the signal output stabilizes following a step change in temperature.
(4) Recommended 0-40° C. Sensors may be stored at -10 to 55° C on an intermittent basis only.
(5) Ex-factory unless agreed to in writing. Under normal application conditions sensor is warranted to be free of defects in material and workmanship for the period specified above proved the sensor is properly installed and operated. Analytical Industries Inc. shall not be liable for buyer's negligence,misapplication, alteration or abuse. The sole remedy for a sensor determined to be defective by Analytical Industries Inc. is limited to replacing the defective sensor.


Long-Life Electrochemical Oxygen Sensor O2 Sensor GPR-11-60