Product Introduction
New high-performance piD-TECH eVx photoionization detector (PID)
1. Upgrades to large range PID photoionization gas sensor PID-10000 include:
• Minimum detectable amount reaches 0.5ppb
• Negligible temperature response
• Very low humidity response
• Overall shielding
• Reduced and improved response time
• Low cost
Intrinsically safe design and 4-series size, for installation in portable or fixed gas detectors.
2. Features and benefits of large range PID photoionization gas sensor PID-10000:
• Intrinsically safe
• Save time and money in R&D and product design
• 4-series product structure
• Multiple ranges and lamp energies
• Circuit for rapid lamp ignition
• Long-life lamp
• Input voltage adjusted for greater stability
• Easy to clean and convenient field service
• Guaranteed sensor replacement procedure
3. Applications of large range PID photoionization gas sensor PID-10000:
• Industrial hygiene & safety detection
• Confined space entry
• Soil contamination and remediation
• Hazardous substance leaks
• Low concentration leak detection
• Indoor air quality
5 different detection levels and 2 different lamp energies provide a wide detection range
| 10.6eV |
Green |
Purple |
Red |
Yellow |
Blue |
| Part number | 045-010 | 045-011 | 045-012 | 045-013 | 045-014 |
| Measuring range | 10000ppm | 2000ppm | 200ppm | 20ppm | 2ppm |
| Minimum detectable amount | 1000ppb | 500ppb | 50ppb | 5ppb | 0.5ppb |
4. Physical characteristics of large range PID photoionization gas sensor PID-10000:
Complete sensor includes detection unit, UV lamp, lamp driver, amplifier, and sampling filter membrane.
| Weight | <8 grams |
| Package structure | 4-series structure |
| Sensor composition | Lamp, detector unit, filter membrane (2), cap, gasket |
| Lamp life | Guaranteed 6000 hours---typical life is longer |
| On-board filter membrane | Filters dust and condensed water |
All sensors are calibrated with isobutylene
5. Electrical parameters of large range PID photoionization gas sensor PID-10000:
| Supply voltage | 3.2~5.5V (including input voltage regulator) |
| Current | 24~36mA |
| Power consumption | 80~200mW (depending on supply voltage) |
| Output signal | 0.045~2.5V |
6. Operating conditions for large range PID photoionization gas sensor PID-10000:
| Temperature range | -20~60°C(-4~104°F) |
| Relative humidity | 0~90%RH non-condensing |
| Humidity Response | ≤1% @ 90%RH |
| Humidity quenching effect | ≤15% @ 90%RH |