UK Alphasense Hydrogen Sulfide Sensor (H2S Sensor) 4-Electrode H2S-A4
UK Alphasense Hydrogen Sulfide Sensor (H2S Sensor) 4-Electrode
UK Alphasense Hydrogen Sulfide Sensor (H2S Sensor) 4-Electrode

UK Alphasense Hydrogen Sulfide Sensor (H2S Sensor) 4-Electrode - H2S-A4

Sensitivity: 1400~1850 nA/ppm
Response Time: <45S
Zero Current: -250 to 100nA
Range: 50ppm
Overload: 100ppm
Linearity Error: < ±0.5ppb

Model: H2S-A4

Product Introduction

1. H2S-A4 Hydrogen Sulfide Sensor (H2S Sensor) Description
Alphasense's hydrogen sulfide gas sensors use fuel cell technology.

H2S-A4 Hydrogen Sulfide Sensor Dimensions:
Diameter 20mm, industrial standard size for portable gas detectors

When measuring current concentration ranges from ppb to 1% H2S, it has high sensitivity and low zero value, enabling accurate and stable readings.

2. H2S-A4 Hydrogen Sulfide Sensor (H2S Sensor) Typical Applications
Air quality trace hydrogen sulfide monitoring, hydrogen sulfide gas transmitters.

3. H2S-A4 Hydrogen Sulfide Sensor (H2S Sensor) Performance

Sensitivity 2ppmH2S,nA/ppm 1400~1850
Response Time t90 From zero to 2ppm H2S (s) <45
Zero Current Output in zero air at 20°C (nA) -250 to 100
Interference* Average interference (ppb) 5
Range H2S warranty detection range (ppm) 50
Linearity Full scale error, linear at 0-110ppm H2S < ± 0.5
Overload Maximum ppm for stable response to gas pulses 100
*Requires low-noise regulated circuit to achieve lower interference and better resolution

4. H2S-A4 Hydrogen Sulfide Sensor (H2S Sensor) Lifespan
Zero Drift Change in ppm per year in laboratory air <±100
Sensitivity Drift Percentage change per year in laboratory air <20
Operating Life Time until output drops to 80% of original signal (months) (warranty 12 months) 24

5. H2S-A4 Hydrogen Sulfide Sensor (H2S Sensor) Environment
Sensitivity at -20°C At 2ppm, (output at -20°C / output at 20°C) % 80-92
Sensitivity at 50°C At 2ppm, (output at 50°C / output at 20°C) % 100-110
Zero at -20°C Change in ppm relative to 20°C 30~50
Zero at 50°C Change in ppm relative to 20°C 90~110

6. H2S-A4 Hydrogen Sulfide Sensor (H2S Sensor) Compatible Sensor Circuit Board:

Analog Front End (AFE) A4 Series Air Quality Sensor - AFE
Based on product design, A4 series air quality sensors need to be used with an analog front end (AFE): Since portable monitoring devices require compact size, we have designed the circuit board with high component density, saving valuable space for your monitoring device. Based on product design, A4 series air quality sensors need to be used with an analog front end (AFE): Since portable monitoring devices require compact size, we have designed the circuit board with high component density, saving valuable space for your monitoring device. Now simply connect the AFE and A4 sensor to a multiplexed ADC to quickly record air quality data.