Product Introduction
1. Typical Applications of Electrochemical Chlorine Gas Sensor CL2-B1
ElectrochemicalChlorine Gas SensorCL2-B1 is used in wastewater treatment and toxic gas measurement in industrial environments.
2. Main Features of Electrochemical Chlorine Gas Sensor CL2-B1
Sensitivity: -600~-1150nA/ppm
Response time: < 60s
Linear range: 20ppm
Overload: 60ppm
Resolution: 0.02ppm
Dimensions: Φ32.3*16.5
Service life: 2 years
Storage period: 6 months
Operating temperature: -20~50℃
Operating humidity: 15~90%RH
Load resistor: 33Ω
3. Main Parameters of Electrochemical Chlorine Gas Sensor CL2-B1
| Performance |
Sensitivity |
10ppmCL2,nA/ppm |
-600~-1150 |
||
| |
Response time |
t90 from zero to 10ppmCL2 (s) |
<60 |
||
| |
Zero current |
ppm content in zero air |
±0.2 |
||
| |
Resolution |
Average noise (ppm) |
< 0.02 |
||
| |
Range |
CL2 warranty detection range (ppm) |
20 |
||
| |
Linearity |
Full scale ppm error, linear at 0-10ppm |
< ± 0.2 |
||
| |
Overload |
ppm for stable response to gas pulses |
60 |
||
| Life |
Zero drift |
ppm change per year in laboratory air |
< 0.03 |
||
| |
Sensitivity drift |
Percentage change per year in laboratory air |
<6 |
||
| |
Operating life |
Time until output drops to 80% of original signal (months) (warranty 24 months) |
> 24 |
||
| Environment |
Sensitivity at -20°C |
At 10ppm CL2, (output at -20°C / output at 20°C) |
70-90 |
||
| |
Sensitivity at 50°C |
At 10ppm CL2, (output at 50°C / output at 20°C)% |
90-105 |
||
| |
Zero at -20°C |
ppm change relative to 20°C |
< 0~ 0.1 |
||
| |
Zero at 50°C |
ppm change relative to 20°C |
<0~-1 |
||
| Cross sensitivity |
H2S |
Percentage sensitivity to 20ppm H2S |
|
||
| |
SO2 |
Percentage sensitivity to 10ppm NO2 |
100 |
||
| |
NO |
Percentage sensitivity to 50ppm NO |
<0.5 |
||
| |
SO2 |
Percentage sensitivity to 20ppm SO2 |
|
||
| |
CO |
Percentage sensitivity to 400ppm CO |
<0.1 |
||
| |
H2 |
Percentage sensitivity to 400ppm H2 |
<0.1 |
||
| |
C2H4 |
Percentage sensitivity to 400ppm C2H4 |
<0.1 |
||
| |
NH3 |
Percentage sensitivity to 20ppm NH3 |
<0.1 |
||
| |
CO2 |
Percentage sensitivity to 5% CO2 |
0 |
||
| Key Parameters |
Temperature range |
℃ |
-20 ~ 50 |
||
| |
Pressure range |
Kpa |
80-120 |
||
| |
Humidity range |
%rh |
15-90 |
||
| |
Storage period |
Sealed storage period at 3-20℃ (months) |
6 |
||
| |
Load resistor |
Ω (recommended) |
33 |
||
| |
Weight |
grams |
<13 |
||