Product Introduction
1. Hydrogen Sulfide Sensor (H2S Sensor)H2S-B4 H2S-B4+ Product Description:
2. Hydrogen Sulfide Sensor (H2S Sensor) H2S-B4 Typical Applications
Trace hydrogen sulfide monitoring in air quality, hydrogen sulfide gas transmitters
Hydrogen Sulfide Sensor (H2S Sensor)H2S-B4 H2S-B4+ Dimensions:

3. Hydrogen Sulfide Sensor (H2S Sensor) H2S-B4Main Parameters
| Sensitivity | 2ppmH2S,nA/ppm | 1450~2600 |
| Response Time | t90 from zero to 2ppm H2S (s) | <60 |
| Zero Current | Output in zero air at 20°C | -250~200 |
| Interference | Average Interference (ppb) | 1 |
| Detection Value | ppb | 1 |
| Range | H2S Warranty Detection Range (ppm) | 100 |
| Linearity
|
ppb value of full-scale error, linear from 0 to 40ppm | < ±4 |
| Overload | ppm of stable response to gas pulses | 200 |
4.Hydrogen Sulfide Sensor (H2S Sensor) H2S-B4Lifetime
| Zero Drift | ppm change per year in laboratory air | <±100 |
| Sensitivity Drift | Percentage change per year in laboratory air | <20 |
| Operating Life | Time until output drops to 80% of original signal (months) (warranty 12 months) | >24 |
5.Hydrogen Sulfide Sensor (H2S Sensor) H2S-B4Environment
| Sensitivity at -20°C | At 2ppm, (output at -20°C / output at 20°C) % | 77-90 |
| Sensitivity at 50°C | At 2ppm, (output at 50°C / output at 20°C) % | 100-110 |
| Zero at -20°C | ppm change relative to 20°C | 50~60 |
| Zero at 50°C | ppm change relative to 20°C | -120~-160 |
6.Hydrogen Sulfide Sensor (H2S Sensor) H2S-B4Cross Sensitivity
| NO2 | Percentage sensitivity to 5ppm NO2 gas | <-10 |
| Cl2 | Percentage sensitivity to 5ppm Cl2 gas | <-12 |
| NO | Percentage sensitivity to 5ppm NO gas | <12 |
| SO2 | Percentage sensitivity to 5ppm SO2 gas | <20 |
| CO | Percentage sensitivity to 5ppm CO gas | <3 |
| H2 | Percentage sensitivity to 100ppm H2 gas | <0.5 |
| C2H4 | Percentage sensitivity to 100ppm C2H4 gas | <0.1 |
| NH3 | Percentage sensitivity to 5ppm NH3 gas | <0.1 |
| CO2 | 5%CO2Percentage sensitivity to measured gas | <0.1 |
7.Hydrogen Sulfide Sensor (H2S Sensor) H2S-B4Key Parameters
| Temperature Range | ℃ | -30~50 |
| Pressure Range | Kpa | 80~120 |
| Humidity Range | %rh | 15~90 |
| Storage Life | Sealed storage life at 3-20°C (months) | 6 |
| Load Resistor | Ω (recommended) | 33~100 |
| Weight | grams | <13 |
Hydrogen Sulfide Sensor (H2S Sensor)H2S-B4 H2S-B4+ IST Board Data

8.Hydrogen Sulfide Sensor (H2S Sensor) H2S-B4Compatible Sensor Board:
Unique Sensor Board (ISB) Alphasense B4 4-Electrode Gas Sensor - ISB
This unique sensor board (ISB) is used for Alphasense B4 series four-electrode gas sensors. The regulator provides dual-channel voltage output.
A low-noise bandgap provides bias voltage for NO sensors, while the ISB can measure oxidizing (CO, H2S, SO2, and NO) and reducing (O3 and NO2) gases.
The ISB is configured in four versions for specific sensors: NO, NO2, O3, and CO/H2S/SO2.