UK Alphasense Hydrogen Peroxide Sensor Hydrogen Peroxide Gas Sensor - H2O2-B1
Measurement Range: 2000ppm
Sensitivity: 50~90nA/ppm
Response Time: < 25s
Linearity: +/-30ppm
Overload: 5000ppm
Resolution: 0.5ppm
Dimensions: Φ32.3*16.5
Service Life: 2 years
Storage Period: 6 months
Operating Temperature: -30~50℃
Operating Humidity: 15~90%RH
Load Resistance: 10-47Ω
Product Introduction
H2O2-B1 Hydrogen Peroxide SensorHydrogen Peroxide Gas Sensor Parameters:
|
Performance |
(Tested with substitute gas CO) |
|||
| Sensitivity |
Sensitivity at 400ppm CO (nA/ppm) |
50~90 |
||
| Response Time |
t90 time from zero to 400ppm CO (s) |
< 25 |
||
| Zero Current |
Equivalent ppm in zero air |
<±4 |
||
| Resolution |
RMS noise (equivalent ppm) |
< 0.5 |
||
| Range |
Measurement limit guaranteeing performance (ppm) |
2000 |
||
| Linearity |
ppm error over full range, linear from 0~1000ppm |
<±30 |
||
| Overload |
Max ppm for stable response to gas pulses |
5000 |
||
| Life |
Zero Drift |
Equivalent ppm change per year in laboratory air |
<0.1 |
|
| Sensitivity Drift |
Percentage change per year in laboratory air, monthly test |
< 3 |
||
| Operating Life |
Months until output drops to 80% of original signal (24-month warranty) |
> 24 |
||
| Environment |
Sensitivity at -20°C |
Output at -20°C / output at 20°C for 400ppm CO (%) |
70~88 |
|
| Sensitivity at 50°C |
Output at 50°C / output at 20°C for 400ppm CO (%) |
102~115 |
||
| Zero at -20°C |
Change in equivalent ppm relative to zero at 20°C |
<±1 |
||
| Zero at 50°C |
Change in equivalent ppm relative to zero at 20°C |
<±6 |
||
| Cross Sensitivity |
H2S |
20ppm H2Sensitivity percentage to measured gas at S |
< 200 |
|
| NO2 |
10ppm NO2Sensitivity percentage to measured gas at |
< 50 |
||
| Cl2 |
10ppm Cl2Sensitivity percentage to measured gas at |
< -1 |
||
| NO |
Sensitivity percentage to measured gas at 50ppm NO |
< 80 |
||
| SO2 |
20ppm SO2Sensitivity percentage to measured gas at |
< 50 |
||
| H2 |
400ppm H2Sensitivity percentage to measured gas at |
< 65 |
||
| C2 H4 |
400ppm C2Sensitivity percentage to measured gas at H 4 |
< 65 |
||
| NH3 |
20ppm NH3Sensitivity percentage to measured gas at |
< 0.1 |
||
| Key Parameters |
Temperature Range |
℃ |
-30~50 |
|
| Pressure Range |
kPa |
80~120 |
||
| Humidity Range |
Continuous Relative Humidity Percentage |
15~90 |
||
| Storage Period |
Months of storage at 3~20℃ (must be stored in sealed container) |
6 |
||
| Load Resistance |
Ω (recommended) |
10~47 |
||
| Weight |
g |
< 13 |
||