Product Introduction
I. Introduction to the infrared carbon dioxide sensor (NDIR CO2 sensor) IRC-AT:
UK Alphasense is a professional manufacturerGas Sensormanufacturer, developed small sizeInfrared CO2 gas sensorUses non-dispersive infrared (NDIR) technology to detect gases. Based on the different absorption rates of infrared spectra by different gases at different concentrations, it detects the presence and concentration of target gases. It is not easily affected by harsh on-site environments. It adopts dual-channel sampling technology, which can self-suppress zero drift. It features long calibration cycles, strong anti-interference capability, high accuracy, high reliability, and long service life.
II. Infrared carbon dioxide sensor (NDIR CO2 sensor) IRC-AT performance:
●Measurement range: 0-5000ppm 0-5%vol 0-20%vol
●Resolution: 25ppm 250ppm 0.4%
●Accuracy: 1%FS 1.5%FS 2.5%FS
●Response time t90: < 40s
●Operating temperature: -20°C to +50°C
●Operating life: > 5 years
●Dimensions: Φ20.0×16.5mm
III.Infrared carbon dioxide sensor (NDIR CO2 sensor) IRC-AT applications:
Suitable for IAQ, industrial safety, vegetable storage, combustion control, and other applications.
IV. Infrared carbon dioxide sensor (NDIR CO2 sensor) IRC-AT performance:
| Power requirements | 5.0VDC, 60mA max (50% duty cycle drive) |
| 工作电压 | 2.0VDC, 20mA max (50% duty cycle drive) |
| Drive frequency | 3Hz |
| Working channel output in N2 (peak-to-peak) | 4-7mV@3Hz, 50% duty cycle |
| Reference channel output in N2 (peak-to-peak) | 2-5mV@3Hz, 50% duty cycle |
| Reaction time (t90) | <40s at 20°C ambient temperature |
| Warm-up time to 0±100ppm: | <30s@20°C |
| Stability: | <30 minutes @20°C |
| Lifespan | >5 years |
V. Infrared carbon dioxide sensor (NDIR CO2 sensor) IRC-ATKey specifications:
| Temperature signal | Thermistor (NTC, R25=100KΩ, Β=3940K) |
| Operating temperature range | -20~50°C (linear compensation -10~40°C) |
| Storage temperature range | -40°C~+75°C |
| Humidity range | 0~95%rh, non-condensing |
VI. Infrared carbon dioxide sensor (NDIR CO2 sensor) model
| Model | Range (application) | Accuracy | Zero point 分辨率 |
Full scale 分辨率 |
Zero point Consistency |
Full scale Consistency |
| IAQ | 0 to 5000ppm (air quality) | 1 | 10ppm | 50ppm | ±20ppm | ±50ppm |
| Other | 0 to 5 % vol (safety) | 1.5 | 10ppm | 100ppm | ±20ppm | ±500ppm |
| 0 to 20 % vol (combustion) | 2.5 | 10ppm | 2000ppm | ±20ppm | ±2500ppm | |
| 0 to 100 % vol (process control) | tbc | 10ppm | tbc | ±20ppm | tbc |