Catalytic combustion sensor MC101
Catalytic combustion sensor

Catalytic combustion sensor - MC101

Bridge output voltage is linear
Fast response speed
Good repeatability and selectivity
Stable and reliable operation
Excellent resistance to H2S and silicone poisoning

Product model: MC101

Product introduction

  • Catalytic combustion sensor MC101 product description

  • The MC101 catalytic element operates based on the principle of catalytic combustion effect. It consists of a detection element and a compensation element paired to form two arms of a bridge circuit. When encountering combustible gas, the resistance of the detection element increases, causing a change in the bridge output voltage. This voltage change increases proportionally with gas concentration, while the compensation element serves as a reference and provides temperature and humidity compensation.

  • Catalytic combustion sensor MC101Sensor features

  • Bridge output voltage is linear

    Fast response speed

    Good repeatability and selectivity

    Stable and reliable operation

    Excellent resistance to H2S and silicone poisoning

  • Catalytic combustion sensor MC101Main applications

  • Concentration detection of combustible gases such as natural gas, liquefied gas, coal gas, alkanes, and organic solvent vapors like gasoline, alcohols, ketones, and benzene in industrial sites. Combustible gas leak alarms; combustible gas detectors; gas concentration meters.

  • Catalytic combustion sensor MC101Technical specifications

  • Product model

    MC101

    Product type

    Carrier catalytic gas sensing element

    Standard packaging

    Plastic packaging

    Operating voltage (V)

    3.0±0.1

    Operating current (mA)

    110±10

    Sensitivity (mV)

    1% methane

    25~50

    1% butane

    30~50

    1% hydrogen

    25~45

    Linearity (%)

    ≤5

    Measurement range (%LEL)

    0~100

    Response time (90%)

    Less than 10 seconds

    Recovery time (90%)

    Less than 30 seconds

    Operating environment

    -40 to +70°C, below 95% RH

    Storage environment

    -20 to +70°C, below 95% RH

    Dimensions (mm)

    Φ12mm×8mm