Catalytic Gas Sensor MC114/114C
Catalytic Gas Sensor

Catalytic Gas Sensor - MC114/114C

Bridge output voltage is linear
Fast response speed
Good repeatability and selectivity
Stable and reliable operation
Excellent resistance to H2S and organic silicon poisoning

Product Model: MC114/114C

Product Introduction

  • Catalytic Gas Sensor MC114/114C Product Description

  • The MC114 catalytic element operates based on the principle of catalytic combustion. It consists of a detection element and a compensation element paired to form two arms of a Wheatstone bridge. When exposed to combustible gases, the resistance of the detection element increases, causing a change in the bridge output voltage. This voltage change increases proportionally with gas concentration. The compensation element serves as a reference and provides temperature and humidity compensation.

  • Catalytic Gas Sensor MC114/114CSensor Features

  • Bridge output voltage is linear

    Fast response speed

    Good repeatability and selectivity

    Stable and reliable operation

    Excellent resistance to H2S and organic silicon poisoning

  • Catalytic Gas Sensor MC114/114CMain Applications

  • Detection of concentration of combustible gases such as natural gas, liquefied gas, coal gas, alkanes, and organic solvent vapors like gasoline, alcohols, ketones, benzene in industrial sites.

    Combustible gas leak alarms; combustible gas detectors; gas concentration meters

  • Catalytic Gas Sensor MC114/114CTechnical Specifications

  • Product Model

    MC114/ MC114C

    Product Type

    Carrier catalytic gas sensor

    Standard Package

    Metal package, metallurgical powder mesh

    Operating Voltage (V)

    2.5±0.1

    Operating Current (mA)

    150±10

    Sensitivity

    (mV)

    1% Methane

    15~35

    1% Butane

    20~40

    1% Hydrogen

    20~40

    Linearity (%)

    ≤5

    Measurement Range (%LEL)

    0~100

    Response Time (90%)

    Less than 10 seconds

    Recovery Time (90%)

    Less than 30 seconds

    Operating Environment

    -40 to +70°C, below 95% RH

    Storage Environment

    -20 to +70°C, below 95% RH

    Dimensions (mm)

    MC114:9.5×14×19

     MC114C: 8×10×14

    Explosion-proof Mark

    ExdibⅠ