Carbon Dioxide Detection Module (CO2 Detection Module) K30
Carbon Dioxide Detection Module (CO2 Detection Module)

Carbon Dioxide Detection Module (CO2 Detection Module) - K30

K30 has 2 analog outputs and 2 digital outputs, flexibly configurable, and can also be configured via SADK or other custom software. K30 offers customization services for various sensing and control devices. The platform is designed as an OEM module that can be embedded in host devices.

Model: K30

Product Introduction

1. Carbon Dioxide Detection Module (CO2 Detection Module) K30 Product Description

The Carbon Dioxide Detection Module (CO2 Detection Module) K30 has 2 analog outputs and 2 digital outputs, flexibly configurable, and can also be configured via SADK or other custom software. K30 offers customization services for various sensing and control devices. The platform is designed as an OEM module that can be embedded in host devices.


2. Carbon Dioxide Detection Module (CO2 Detection Module) K30 Performance and Technical Parameters

Operating Principle
Working Principle

Non-dispersive infrared (NDIR)
Non-Dispersive Infrared (NDIR)

Measured gas
Measured Gas

Carbon dioxide (CO2)
Carbon Dioxide (CO2)

Measurement range CO2
CO2 Measurement Range

0 to 5000 ppm / 0 to 3%vol
0-5000 ppm / 0-3%vol

Accuracy
Accuracy

±30 ppm ±3% of reading
±30 ppm ±3% of reading

Dimensions
Dimensions

57 mm x 51 mm x 14 mm
57 mm x 51 mm x 14 mm

Maintenance
Maintenance

Maintenance-free*
- Maintenance-free

Life Expectancy
Service Life

> 15 years
> 15 years

Operation temperature range
Operating Temperature Range

0 to 50 °C
0-50 °C

Operation humidity range
Operating Humidity Range

0 to 95% RH (non-condensing)
0-95% RH (non-condensing)

Power supply
Power Supply

4.5 to 14.0 V DC
4.5-14.0 V DC

Response time(T1/e)
Response Time (T1/e)

20 sec diffusion time
20 seconds diffusion time

Warm-up time
Warm-up Time

1 min
1 minute

Communication
Communication

Uart ( Modbus)
Universal Asynchronous Receiver/Transmitter (Modbus)

Outputs
Outputs


OUT 1 linear output
OUT 1 Linear Output

0 to 4 V DC = 0 to 2000 ppm
0-4V DC = 0-2000 ppm

OUT 2 linear output
OUT 2 Linear Output

1 to 5 V DC = 0 to 2000 ppm
1-5V DC = 0-2000 ppm

OUT 3 digital output
OUT 3 Digital Output

700/800 ppm
700/800 ppm

OUT 4 digital output
OUT 4 Digital Output

900/1000 ppm
900/1000 ppm

*Maintenance-free with using SenseAir ABC logic Self calibration using for normal indoor applications.
*Maintenance-free operation using SenseAir ABC Logic automatic calibration is only for normal indoor applications.