It is designed to work with plug-in sensor modules for 0-0.1ppm, 0-1ppm, and 0-10ppm. When ordering, specify these by placing the ppm range after the model number.

Product Model: OEM-1

Product Introduction

US ECO Ozone Sensor OEM-1 Description:
Model OEM-1 is a system that controls an ozone generator and alarm based on an adjustable ozone concentration setpoint. It is designed to work with plug-in sensor modules for 0-0.1ppm, 0-1ppm, and 0-10ppm. When ordering, specify these by placing the ppm range after the model number. For example, a 1 ppm OEM-1 board system would be OEM-1. The replacement sensor module is SM-1-1. These same sensor modules also work with our OEM-2 board, which has features such as 4-20 mA output. The sensor module can also be located at a distance from the OEM-1 board via 2-meter or 8-meter cables. These are off-the-shelf DIN M/F 5-pin extension cables.
One component of the OEM-1 system is the base board, which includes power supply, final signal processing, setpoint control, and output relays. Another component is the sensor, which is mounted in a cylindrical DIN plug with associated electronics. It is pre-calibrated in our laboratory so that the sensor module and main board module work together as a calibrated system. If the sensor module is damaged, simply replace it with another pre-calibrated module.
The design includes hysteresis and time delay (set to 8 seconds, except on special order) to eliminate chatter and other excessive interaction between the sensor and generator. The SPDT relay contacts will handle up to 5 amps at 250 volts. The OEM-1 should not be used outdoors or in the presence of NOx, nitric acid, acid gases, or halogen compound fumes.


US ECO Ozone Sensor OEM-1 Specifications:

Sensors

Heated metal oxide semiconductor

Accuracy

20%.

Range

0-0.1ppm, 0-1ppm, and 0-10ppm available.

Sensitivity

As low as 0.02 ppm for 0.1 ppm module, 0.1 ppm for 1 ppm module, 0.3 ppm for 10 ppm module. These sensitivities will be reduced if sensor module extension cables are used.

Response Time

Within 10 seconds

Switch Delay

8 seconds standard. Other times on request.

Temperature and Humidity Range

This correction applies only to normal room temperature and humidity.
The circuit does not include temperature or humidity compensation. Power supply voltage requirement: 110 VAC
or 220 VAC per OEM specification. Alternatively, 12 VDC at 300 mA.

Relay Rating

Non-latching. Contacts 5 amps at 250 VAC.

Main Board Dimensions

83 x 83 mm (3.25" x 3.25"). Requires 23 mm (.875") clearance from the top of the board and 6 mm (.250")
clearance from the bottom surface of the board.

Main Board Mounting

Secure with 4 3.5 mm screws (or 6-32 screws).

Sensor Modules

16 mm (dia) X45 mm (length), (.62” X 1.75”), 10 g (.3 oz)

Shipping Weight

Module and 2-meter sensor extension cable, without adapter: 454 g (1 lb)