Japan Figaro Long-Life Lead-Free Battery-Type Oxygen Sensor KE-25LF, KE-25F3LF
Japanese Figaro long-life lead-free battery-type oxygen sensor
Japanese Figaro long-life lead-free battery-type oxygen sensor

Japan Figaro Long-Life Lead-Free Battery-Type Oxygen Sensor - KE-25LF, KE-25F3LF

Lead-free galvanic battery-type sensor
Sensor operation requires no external power supply
No warm-up time required
Complies with RoHS2 standards

Product Model: KE-25LF,KE-25F3LF

Product Introduction

Description of Japan Figaro Long-Life Lead-Free Battery-Type Oxygen Sensor KE-25LF, KE-25F3LF:

The oxygen sensor KE-LF series (KE-25LF and KE-25F3LF) is a unique galvanic battery-type oxygen sensor developed by Maxell Corporation, Japan. Its notable features include being lead-free, having a long service life, excellent chemical stability, and being unaffected by CO2 interference. The KE-LF series oxygen sensors were developed to meet the growing demand for oxygen detection across various industries, such as combustible gas monitoring, biotechnology applications, residential gas appliances, and more.


Features of Japan Figaro Long-Life Lead-Free Battery-Type Oxygen Sensor KE-25LF, KE-25F3LF:

Lead-free galvanic battery-type sensor
Sensor operation requires no external power supply
No warm-up time required
Complies with RoHS2 standards
Weak acidic electrolyte
Almost unaffected by CO2, H2S, SO2
Long life, 3-5 years in air environment


Applications of Japan Figaro Long-Life Lead-Free Battery-Type Oxygen Sensor KE-25LF, KE-25F3LF:

Safety field - oxygen detectors

Environmental control - combustible gas monitoring
Food industry - refrigerants, greenhouses

Teaching equipment - oxygen experiment kits


Parameters of Japan Figaro Long-Life Lead-Free Battery-Type Oxygen Sensor KE-25LF, KE-25F3LF:

Item

Model

KE-12F3LF

KE-25LF

KE-25F3LF

KE-50LF

KE-25F3LFM

Detection range

0~30% O2

0~100% O2

Accuracy (Note 1)

±1% (full scale)

±1% (full scale)

±2% (full scale)

±1% (full scale)

Operating conditions

Atmospheric pressure

811hPa~1216hPa

Temperature

5~40˚C

Relative humidity

10~90%RH (non-condensing)

Response time (90%) (Note 2)

approximately8 seconds

approximately15 seconds

approximately60 seconds

approximately15 seconds

Under factory test conditions

Initial output voltage

9.0~15.0mV

10.0~15.5mV

4.5~7.5mV

5.0~8.0mV

20˚C In normal air

Expected life(Note 3)

approximately3 years

approximately5 years

approximately10 years

approximately6 years

Factory test

Conditions

Test gas

21% O2

 

Atmospheric pressure

1013hPa

 

Temperature

25˚C



Notes:

1) If used0%with30%If calibrated with two oxygen concentrations, the measurement range covers oxygen content0~30%whenKE-12F3LFwithKE-25LF/KE-25F3LFFull-scale accuracy is±1%,KE-50LFFull-scale accuracy is±2%. If used0%with100%If calibrated with two oxygen concentrations, the measurement range covers oxygen content0~100%whenKE-25F3LFMFull-scale accuracy is±1%。

2) To meet the response speed in the specification sheet, the sensor should be used under conditions where the air exchange rate is greater than200~300ml/under conditions of minutes.

3)20˚CNormal air (1013 hPa / 21%O2) The expected life refers to the period when the sensor output value drops to the initial value70%during this period.


Please refer toMaxell KE-LFcontent regarding limited warranty and liability in the series oxygen sensor technical manual;

*KE-LFThe series oxygen sensors are designed, manufactured, and tested for industrial applications, and the design, manufacturing, testing, and use of the products are not intended for ventilators, respirators, and/or other medical devices, including modules, components, or parts used therein.