Product introduction
High-precision digital pressure transmitter CS-PT606 product features and application areas
0.25%F.S, 0.1%F.S accuracy; high precision, high quality; RS485 output; analog voltage output; high temperature stability.
Applications: aerospace, hydrological testing, geological exploration, petrochemical, mining machinery.
High-precision digital pressure transmitter CS-PT606Product description
CS-PT606 series pressure transmitters use internationally high-quality sensor cores, transmitter-specific integrated circuits and accessories, and utilize military-grade production lines and processes to produce high-precision, high-quality, compact, easy-to-install, simple-to-use, and cost-effective pressure transmitters.
CS-PT606 digital pressure transmitter uses a high-performance MCU, high-precision ADC and DAC, and after temperature compensation, can achieve 0.1% and 0.25% accuracy over the full temperature range of -40℃ to 85℃ or the normal temperature range of -10℃ to 60℃. With software correction, even higher accuracy can be achieved. It has RS485 digital and analog dual outputs, RS485 flexible networking and provides host computer test software, and the analog part can be freely configured to any range within 0V to 5VDC.
High-precision digital pressure transmitter CS-PT606Technical parameters
| General |
Value |
Remarks |
| Pressure range |
0~2MPa……100MPa |
1MPa=10bar 1bar≈14.5PSI 1PSI=6.8965kPa 1kgf/cm2=1 atmosphere |
| Accuracy |
0.25%F.S、0.1%F.S |
|
| Overload pressure |
1.5 times rated pressure (1.5X) |
|
| Burst pressure |
3 times rated pressure (3X) |
|
| Power supply |
10~30Vdc |
|
| Operating current |
<10mA |
|
| Compensated temperature |
-10℃~60℃、-40℃~85℃ |
|
| Analog output |
0-5VDC |
(adjustable) |
| Digital output |
RS485 |
|
| Operating temperature |
-40~80℃ |
|
| Electrical connection |
Aviation plug |
|
| Pressure port |
M20×1.5、G1/4、G1/2、R1/2、NPT1/2 |
Customizable |
| Protection class |
IP65 |
|
| Stability |
0.15%F.S |
|
| Pressure type |
Gauge G, sealed gauge S |
|
| EMC |
EM radiation: EN50081-1/-2; EM immunity: EN50082-2 |
|