Home chevron_right Sensors chevron_right Gas Sensor 
Industrial residual chlorine transmitter AMT/RS-CL
Industrial residual chlorine transmitter

Industrial residual chlorine transmitter - AMT/RS-CL

Industrial residual chlorine transmitter

Product Model: AMT/RS-CL

Product Introduction

Residual chlorine measurement range is 0-2mg/L, 0-10mg/L, 0-20mg/L optional, resolution 0.01mg/L;

Adopts advanced non-membrane constant voltage sensor, no need to replace membrane or reagents;

3/4 top and bottom mounting thread design, easy to install;

The device adopts wide voltage power supply DC 10~30V (0~10V voltage output requires DC24V power supply).

485 type:

Power supply DC 10~30V
Power consumption 0.3W
Communication interface RS485; standard ModBus-RTU protocol; communication baud rate: 2400, 4800, 9600 configurable; default 4800
Free chlorine concentration measurement range 0-2mg/L, 0-10mg/L, 0-20mg/L optional, resolution 0.01mg/L
Residual chlorine measurement error 5% or 0.05mg/L, whichever is greater
Repeatability error ±0.05mg/L
Response time <30s
Transmitter element temperature and humidity resistance -20℃~+80℃,0%RH~95%RH (non-condensing)
Electrode applicable temperature 0~50℃
Electrode pressure resistance 0.6MPa
Electrode cable length Default 5m (10m, 15m, 20m customizable)
Electrode lifespan 1 year

 

Analog type:

Power supply DC 10~30V (0~10V voltage output requires DC24V power supply)
Power consumption 0.9W
Output signal Current output 4~20mA
Voltage output 0~5V/0~10V
Load capacity Current output ≤600Ω
Voltage output Output resistance ≤250Ω
Free chlorine concentration measurement range 0-2mg/L, 0-10mg/L, 0-20mg/L optional, resolution 0.01mg/L
Residual chlorine measurement error 5% or 0.05mg/L, whichever is greater
Repeatability error ±0.05mg/L
Response time <30s
Transmitter element temperature and humidity resistance -20℃~+80℃,0%RH~95%RH (non-condensing)
Electrode applicable temperature 0~50℃
Electrode pressure resistance 0.6MPa
Electrode cable length Default 5m (10m, 15m, 20m customizable)
Electrode lifespan 1 year


4G type:

Power supply DC 10~30V
Power consumption 0.5W
Free chlorine concentration measurement range 0-2mg/L, 0-10mg/L, 0-20mg/L optional, resolution 0.01mg/L
Residual chlorine measurement error 5% or 0.05mg/L, whichever is greater
Repeatability error ±0.05mg/L
Response time <30s
Transmitter element temperature and humidity resistance -20℃~+80℃,0%RH~95%RH (non-condensing)
Electrode applicable temperature 0~50℃
Electrode pressure resistance 0.6MPa
Electrode cable length Default 5m (10m, 15m, 20m customizable)
Electrode lifespan 1 year
Data upload time Default 60s/time, 1s~65535s configurable
Data collection time 2s/time


WIFI type:

Power supply DC 10~30V
Power consumption 0.5W
Free chlorine concentration measurement range 0-2mg/L, 0-10mg/L, 0-20mg/L optional, resolution 0.01mg/L
Residual chlorine measurement error 5% or 0.05mg/L, whichever is greater
Repeatability error ±0.05mg/L
Response time <30s
Transmitter element temperature and humidity resistance -20℃~+80℃,0%RH~95%RH (non-condensing)
Electrode applicable temperature 0~50℃
Electrode pressure resistance 0.6MPa
Electrode cable length Default 5m (10m, 15m, 20m customizable)
Electrode lifespan 1 year
Data upload time Default 10s/time, 1s~65535s adjustable
Data collection time 2s/time
WIFI communication parameters 802.11b/g/n
Security Security mode WEP/WPA-PSK/WPA2-PSK Encryption type WEP/TKIP/AES

 

LORA type:

Power supply DC 10~30V
Power consumption 0.5W
Free chlorine concentration measurement range 0-2mg/L, 0-10mg/L, 0-20mg/L optional, resolution 0.01mg/L
Residual chlorine measurement error 5% or 0.05mg/L, whichever is greater
Repeatability error ±0.05mg/L
Response time <30s
Transmitter element temperature and humidity resistance -20℃~+80℃,0%RH~95%RH (non-condensing)
Electrode working conditions Temperature: 0~50℃
PH:4-9
Pressure: ≤0.6MPa
Flow rate: 30~60L/h (flow-through cell installation)
Electrode cable length Default 5m (10m, 15m, 20m customizable)
Electrode lifespan 1 year