Home chevron_right Sensors chevron_right Gas Sensors chevron_right Oxygen Sensors chevron_right Zirconia Oxygen Sensors 
UK SST Zirconia Oxygen Sensor O2 Sensor NPT Probe Series Threaded Mounting Housing O2S-FR-T2-34NPTA-XXX
UK SST Zirconia Oxygen Sensor O2 Sensor NPT Probe Series Threaded Mounting Housing

UK SST Zirconia Oxygen Sensor O2 Sensor NPT Probe Series Threaded Mounting Housing - O2S-FR-T2-34NPTA-XXX

Zirconia (ZrO2) Sensing Element
Long life, non-consumable technology
Integral heating element
High accuracy

Model: O2S-FR-T2-34NPTA-XXX

Product Introduction

UK SST Zirconia Oxygen Sensor O2 Sensor NPT Probe Series Threaded Mounting HousingO2S-FR-T2-34NPTA-XXX Features:

Zirconia (ZrO2) sensing element

Long life, non-consumable technology

Integral heating element

High accuracy

Requires external interface board to operate



UK SST Zirconia Oxygen Sensor O2 Sensor NPT Probe Series Threaded Mounting HousingO2S-FR-T2-34NPTA-XXX  Advantages:

No reference gas required

No temperature stabilization required

3/4" NPT threaded mounting



UK SST Zirconia Oxygen Sensor O2 Sensor NPT Probe Series Threaded Mounting HousingO2S-FR-T2-34NPTA-XXX Specifications:

Heater Voltage


Operating (standard response)

4.35VDC± 0.1VDC(1.85A)

Standby

2VDC(0.85A)

Standby

2VDC(0.85A)

Pump impedance at 700°C

< 6kΩ

Allowable gas temperature

-100°C~+250°C

Gas flow rate

0—10 m/s

Repeatable allowable acceleration

5g

Occasional allowable acceleration

30g

Oxygen pressure range

2mbar—3bar max

Accuracy

5mbar max

Internal operating temperature

700°C

Response time (10-90% step)


Standard response sensor

< 15s

Fast response sensor

<4s

Warm-up time (before sensor operation)

60s

Warm-up time (standby wake-up)

20s

Output stabilization time

180s


UK SST Zirconia Oxygen Sensor O2 Sensor NPT Probe Series Threaded Mounting HousingO2S-FR-T2-34NPTA-XXX Dimensions:



UK SST Zirconia Oxygen Sensor O2 Sensor NPT Probe Series Threaded Mounting HousingO2S-FR-T2-34NPTA-XXX Selection: