French LCJ Capteurs Ultrasonic Anemometer - SONIC-ANEMO-SDI
Traditional anemometers have rotating mechanical parts. These moving parts are prone to damage. Ultrasonic sensors are designed
to avoid any mechanical parts to ensure more reliable operation. Ultrasonic sensors offer long-term stability without
maintenance.
Product Introduction
I. French LCJ Capteurs Ultrasonic Anemometer SONIC-ANEMO-SDI Working Principle:
Traditional anemometers have rotating mechanical parts. These moving parts are prone to damage.Ultrasonic SensorsDesigned to avoid any mechanical parts to ensure more reliable operation. Ultrasonic sensors offer long-term stability without maintenance.
Sound is transmitted by the moving object at the intersection. Electroacoustic sensors (1) communicate with each other using ultrasonic signals (2) along orthogonal axes, where wind speed (3) causes different transmission times. The CV7 sensor communicates 4 different tests between them, and the headwind obtained from the tests is used for calculation. The combined measurements calculate wind speed and wind direction based on the base axis. Temperature measurement is used for calibration. The sensor design reduces the influence of tilt angle (4) (the effect of sensor tilt can be partially corrected due to the spatial shape of the sensor).The CV7 transmits 4 independent test data. A correctness check is used for the calculation of the headwind vector. This method gives a wind speed sensitivity of 0.15 m/s and excellent linearity up to 40 m/s.
II. French LCJ Capteurs Ultrasonic Anemometer SONIC-ANEMO-SDI Optional Components:
These industrial accessories are as follows:
• Connector for 24VDC/AC power supply * 1
• Connector for CV7-V data * 1
• 12V connector for CV7-V power supply * 1
• Galvanic isolation between power supply and analog output
• Galvanic isolation between power supply and sensor power supply
• Sensor input is optocoupled
• 420 AC
III.Features of French LCJ Capteurs Ultrasonic Anemometer SONIC-ANEMO-SDI Optional Components:
•1 4~20mA output current corresponding to wind speed range of 0.25Kts~80Kts, with CV7 test check
•1 4~20mA output current corresponding to wind direction range of 0~359°, with CV7 test check
•2 Dry contact for wind speed alarm
ANA-AC
This optional component features 3 0~10V outputs:
• 0~15m/s
• 0~30m/s or 0~40m/s selectable
• 0~359° wind direction
IV. French LCJ Capteurs Ultrasonic Anemometer SONIC-ANEMO-SDI Parameters:
| Output Data Format |
SDI-12 V1.3 |
| Data Transmission |
Instant. W. Speed, Instant. W. Angle, avaibility |
| Output Rate |
2Hz/30Hz |
| Wind Speed Sensitivity |
0.12 m/s |
| Wind Speed Resolution |
0.05 m/s |
| Range |
0.12 to 40 m/s |
| Wind Direction Sensitivity |
+/-1.5° |
| Wind Direction Resolution |
1° |
| Power Supply |
2.7~35VDC |
| Current Consumption |
2.9mA average @12V |
| Operating Temperature |
-15°C ~ +55°C |
| Cable Length |
5m / 3*0.22 mm2 UV protected |
| Interface |
3-wire |
| Head Weight |
N/A |
| Product Component Weight |
200g with mounting parts |
| Mounting |
Vertical, 300mm aluminum arm, Ø 16 mm |