Product Model: AMT/PH-300

Product Introduction

Ceramic Pickling Wastewater pH Sensor, Hydrofluoric Acid Resistant, RS485 Communication Output

I. Ceramic Pickling Wastewater pH Sensor, Hydrofluoric Acid Resistant, RS485 Communication Output Product Overview

Ceramic Pickling Wastewater pH Sensor, Hydrofluoric Acid Resistant, RS485 Communication Output adoptsComposite glass electrode principle(indicating electrode + Ag/AgCl Reference electrode+ built-in temperature compensation), follows the Nernst equation, collects the hydrogen ion activity of the solution in real time, and has a built-in microprocessor that directly digitizes the signal, achieving high-precision, stable and continuous online pH monitoring. The product integrates automatic temperature compensation (ATC), greatly eliminating measurement deviation caused by temperature, supporting long-term immersion installation, suitable for industrial processes, environmental water quality, food and pharmaceuticals, etc.pH scenarios with strict accuracy requirements, can be directly connected toPLC、DCS、data acquisition terminal, is the core sensing unit for automated water quality control.

II. Ceramic Pickling Wastewater pH Sensor, Hydrofluoric Acid Resistant, RS485 Communication Output Working Principle

When the sensitive glass membrane contacts the solution to be measured, the hydrogen ion concentration difference on both sides of the membrane generates a potential difference; the reference electrode provides a stable reference potential; built-in NTC/PT1000 The temperature element synchronously collects liquid temperature, and the algorithm automatically compensates for temperature drift, converting the potential signal into standardpH value; digital probe completes signal conversion locally, reducing electromagnetic interference in long-line transmission.

III. Ceramic Pickling Wastewater pH Sensor, Hydrofluoric Acid Resistant, RS485 Communication Output Core Features

  1. High measurement accuracy:Range 0~14pH,Accuracy ±0.02pH,分辨率0.01pHgood repeatability, suitable for precision process control and laboratory-grade online monitoring
  2. Automatic temperature compensation ATC:Built-in temperature sensing, full-temperature-range correction, stable data under high and low temperature conditions
  3. Excellent anti-interference:Built-in high-impedance amplifier circuit, digital RS485 Modbus-RTU output, strong anti-electromagnetic interference, signal does not attenuate over long-distance transmission; some models have electrical isolation
  4. Corrosion-resistant structure:PPS Engineering plastic housing,PTFE Porous liquid junction, not easy to clog, resistant to weak acids and weak bases; optional sanitary-grade and special anti-corrosion electrodes
  5. Intelligent storage:Onboard memory, saves calibration parameters, not lost after power failure; supports reading electrode diagnostic information (slope, zero point, contamination status)
  6. Easy installation: Standard G3/4 orNPT3/4 Threaded, supports multiple installation methods such as flow cell, immersion, and pipe insertion; protection ratingIP68can be used immersed in water for a long time
  • Technical parameters

Item

Parameter

Measurement Range

0 ~ 14 pH

Measurement accuracy

±0.02 pH(25℃)

分辨率

0.01 pH

Temperature range

0 ~ 60℃ (optional high-temperature model)

Temperature Accuracy

±0.3℃

Power supply

5~24VDC

信号输出

RS485 Modbus-RTU / 4-20mA analog optional

Housing material

PPS (optional 316L stainless steel)

Liquid junction

PTFE porous diaphragm

Withstand Pressure

≤3bar

防护等级

IP68

Response time

≤10s (95% stable value)

 

V.Application fields

✅ Environmental Protection Industry: Online monitoring of wastewater plant inlet and outlet water, surface water, river water quality, discharge outlets✅ Water treatment: pure water/ Ultrapure water, circulating cooling water, reverse osmosis processpH Precision control✅ Chemical and Metallurgy: Reactor pH monitoring, acid-base neutralization processes✅ Food and Pharmaceutical: Beverages, fermentation, biopharmaceuticals, sanitary processespH monitoring (sanitary electrode)✅ Aquaculture: Aquaculture water bodiespH Real-time monitoring✅ Laboratories, scientific research equipment, water quality online monitoring stations

Six,Usage and maintenance tips

  1. Factory pre-calibrated; before on-site use, it is recommended to use standard buffer solution (4.01、6.86、9.18) two-point calibration
  2. The glass sensitive membrane must not be stored dry; for long-term disuse, it must be soaked in protective solution
  3. For sewage and high-turbidity conditions, regularly clean the diaphragm to prevent drift caused by scaling and clogging
  4. Avoid prolonged immersion of the glass bulb in strong hydrofluoric acid or high-concentration strong alkali

 

Main Application Areas

  • Ceramic Pickling Wastewater Treatment — Monitors pH in highly corrosive hydrofluoric acid-containing wastewater from ceramic pickling processes, ensuring compliance and process control.
  • Chemical Manufacturing — Used in chemical plants for pH control in aggressive acid and alkali streams, including HF-containing solutions.
  • Metal Surface Treatment — Ideal for pickling, etching, and plating baths where hydrofluoric acid and other strong acids are present.
  • Environmental Water Monitoring — Suitable for industrial effluent monitoring and environmental compliance in wastewater treatment plants.
  • Pharmaceutical and Fine Chemical Production — Provides reliable pH measurement in reactors and process lines handling corrosive chemicals.

Keywords:ceramic pickling wastewater pH sensor, hydrofluoric acid resistant pH probe, RS485 pH sensor, industrial pH sensor, wastewater pH monitoring, HF resistant pH electrode, digital pH sensor, water quality pH sensor