Product Model: AMT/RS-SF6*-*-2/OLED

Product Introduction

Range of 0~1000ppm, high measurement accuracy, repeatability within 2%.
 

Calibrated with standard gas, it features long lifespan, high precision, high repeatability, and high stability.
 

Devices with high-quality OLED display (optional) allow direct viewing of values through the screen, clearly visible even at night.


Adopts 10~30V DC wide voltage power supply, adaptable to various DC power sources on site.

485 type:

Power supply 10~30V DC
Average Power Consumption 0.95W
Output signal 485
SF6 resolution 1ppm
SF6 maximum permissible error 0~1000ppm:±10% (@500ppm,60%RH,25℃)
0~2000ppm:±10% (@2000ppm,60%RH,25℃)
SF6 range 0~1000ppm
Temperature Accuracy ±0.5℃(25℃)
Humidity accuracy ±3%RH(60%RH,25℃)
Temperature measurement range -40℃~+80℃
Humidity measurement range 0~100%RH
Zero Drift ±3ppm
工作温度 -20~50℃
Working humidity 15~95%RH (non-condensing)
Stability ≤2% signal value/month
Response time ≤30s
SF6 typical warm-up time ≥30min
Repeatability ≤3%
Pressure range 90~110kPa

Analog type:

Power supply 10~30V DC (0~10V output type uses 24V power supply)
Maximum power consumption 1.78W
Output signal 4~20mA、0~5V、0~10V
SF6 maximum permissible error 0~1000ppm:±10% (@500ppm,60%RH,25℃)
0~2000ppm:±10% (@2000ppm,60%RH,25℃)
SF6 range 0~1000ppm
Zero Drift ±3ppm
工作温度 -20~50℃
Working humidity 15~95%RH (non-condensing)
Stability ≤2% signal value/month
Response time ≤30s
SF6 typical warm-up time ≥30min
Repeatability ≤3%
Pressure range 90~110kPa

WiFi type:

Power supply 10~30V DC
Output signal WIFI
SF6 resolution 1ppm
SF6 maximum permissible error 0~1000ppm:±10% (@500ppm,60%RH,25℃)
0~2000ppm:±10% (@2000ppm,60%RH,25℃)
SF6 range 0~1000ppm/2000ppm/3000ppm
Temperature Accuracy ±0.5℃(25℃)
Humidity accuracy ±3%RH(60%RH,25℃)
Temperature measurement range -40℃~+80℃
Humidity measurement range 0~100%RH
Zero Drift ±3ppm
工作温度 -20~50℃
Working humidity 15~95%RH (non-condensing)
Stability ≤2% signal value/month
Response time ≤30s
SF6 typical warm-up time ≥30min
Repeatability ≤3%
Pressure range 90~110kPa
WIFI communication parameters 802.11b/g/n
Security Security mode WEP/WPA-PSK/WPA2-PSK Encryption type WEP/TKIP/AES
Configuration tool Multi-function parameter configuration

Main Application Areas

  • SF6 Gas Insulated Switchgear — Monitors SF6 gas concentration and leakage in GIS and high-voltage switchgear to ensure safe operation and prevent insulation failures.
  • Power Plants and Substations — Provides continuous SF6 leak detection in electrical power facilities, protecting personnel and equipment from gas accumulation.
  • Industrial Gas Monitoring — Used in semiconductor manufacturing, magnesium casting, and other industrial processes where SF6 is generated or utilized.
  • Environmental Monitoring — Tracks SF6 emissions in compliance with environmental regulations due to its high global warming potential.
  • Laboratory and Research — Enables precise SF6 concentration measurement in research settings for gas analysis and experimental studies.

Keywords:SF6 transmitter, sulfur hexafluoride sensor, SF6 gas detector, SF6 leak monitor, industrial SF6 transmitter, SF6 concentration meter, OLED SF6 sensor, SF6 gas analyzer