UK Alphasense High Resolution Nitric Oxide Sensor (NO Sensor) NO-A4
UK Alphasense High Resolution Nitric Oxide Sensor (NO Sensor)
UK Alphasense High Resolution Nitric Oxide Sensor (NO Sensor)

UK Alphasense High Resolution Nitric Oxide Sensor (NO Sensor) - NO-A4

High Resolution
Good Linearity
High Sensitivity

Model: NO-A4

Product Introduction

I. Description of High Resolution Nitric Oxide Sensor NO-A4

NO-A4 is a high-resolutionnitric oxide sensorin 4-series size, ideal for environmental air quality monitoring systems and instruments.


II. Main Parameters of High Resolution Nitric Oxide Sensor NO-A4

Sensitivity: 250-425 nA/ppm

Response Time: < 25s

Dimensions: Φ20.2×16.5

Zero Current: 10-80nA

Range: 20ppm

Overload: 50ppm


III. Typical Applications of Nitric Oxide Sensor NO-A4

Trace nitric oxide monitoring in air quality, nitric oxide gas transmitters.


IV. Performance of High Resolution Nitric OxideSensor(NOSensor)NO-A4

Sensitivity nA/ppm@2ppmNO 250~425
Response Time t90 from zero to 1ppm NO (s) <25
Zero Current In zero air at 20°C (nA) 10~80
Noise Average noise (ppb) 80
Detection Limit ppb 80
Range NO warranty detection range (ppm) 20
Linearity Error in ppm over full range, linear from 0-5ppm <±1
Overload Maximum ppm for stable response to gas pulses 50

A low-noise voltage regulator circuit is required to minimize interference and achieve better resolution.


V.High Resolution Nitric OxideSensor(NOSensor)NO-A4Lifetime

Zero Drift Annual change in ppb in laboratory air 0~50
Sensitivity Drift Annual percentage change in laboratory air 0~-20
Operating Life Time until output drops to 80% of original signal (months) (warranty 24 months) >24


VI.High Resolution Nitric OxideSensor(NOSensor)NO-A4Environment

Sensitivity at -20°C At 2ppm NO, (output at -20°C / output at 20°C) % 35~60
Sensitivity at 50°C At 2ppm NO, (output at 50°C / output at 20°C) % 120~135
Zero at -20°C Change in ppm relative to 20°C -10~-50
Zero at 50°C Change in ppm relative to 20°C 200~350


VII.High Resolution Nitric OxideSensor(NOSensor)NO-A4Cross Sensitivity

H2S Percentage sensitivity to 20ppm H2S <30
Cl2 Percentage sensitivity to 10ppm Cl2 <5
NO2 Percentage sensitivity to 10ppm NO2 (after 3 minutes) <3
SO2 Percentage sensitivity to 20ppm SO2 <4
CO Percentage sensitivity to 10ppm CO <0.3
H2 Percentage sensitivity to 400ppm H2 <0.1
NH3 Percentage sensitivity to 20ppm NH3 <0.1
CO2 Percentage sensitivity to 5% CO2 <0.1
Halothane Percentage sensitivity to 100ppm halothane <0.1


VIII.High Resolution Nitric OxideSensor(NOSensor)NO-A4Key Parameters

Bias Voltage mV (working electrode potential relative to reference electrode) 200
Temperature Range ℃ -30~50
Pressure Range Kpa 80-120
Humidity Range %rh 15~85
Storage Life Sealed storage life at 3-20°C (months) 6
Load Resistor Ω (recommended) 33-100
Weight grams <6



IX.High Resolution Nitric OxideSensor(NOSensor)NO-A4Companion Sensor Circuit Board:

Analog Front End Circuit (<font color='red'>AFE</font>) <font color='red'>A4</font> Series Air Quality Sensors

Analog Front End Circuit(AFE) A4Series Air Quality Sensors -AFE

Based on product design, A4 series air quality sensors require an analog front-end circuit (AFE): Since portable monitoring devices require compact size, we designed the circuit board with high component density to save valuable space for your monitoring device. Based on product design, A4 series air quality sensors require an analog front-end circuit (AFE): Since portable monitoring devices require compact size, we designed the circuit board with high component density to save valuable space for your monitoring device. Now simply connect the AFE and A4 sensor to a multiplexed ADC to quickly record air quality data.