AMT-101 Portable Multi-parameter Water Quality Analyzer - AMT-101
AMT-101 portable multi-parameter water quality analyzer is an instrument for **rapid on-site field water quality testing**, divided into two categories: **electrochemical electrode type** and **spectrophotometric colorimetric type**. It is portable/handheld, with built-in battery, no laboratory required, and can directly test water samples at rivers, sewage plants, and emergency sites.
Product Introduction
# Portable Multi-Parameter Water Quality Analyzer
AMT-101 portable multi-parameter water quality analyzer is an instrument for **rapid on-site field water quality testing**, divided into two categories: **electrochemical electrode type** and **spectrophotometric colorimetric type**. It is portable/handheld, with built-in battery, no laboratory required, and can directly test water samples at rivers, sewage plants, and emergency sites.
## Two Major Types
### 1. Electrochemical Electrode Type (handheld probe, no reagents required)
**Can measure: pH, ORP oxidation-reduction potential, dissolved oxygen DO, conductivity, TDS, salinity, temperature, turbidity**, some can connect ion electrodes to measure ammonia nitrogen, nitrate nitrogen, chloride ions, etc.
- Principle: ion-selective electrode, directly immersed in water for reading, **no reagents, instant results**
- Advantages: fast speed, no consumables, suitable for continuous field monitoring;
- Disadvantages: cannot measure heavy metals, COD, total phosphorus, total nitrogen; electrodes require periodic calibration and are prone to contamination.
>
> Representative: Hach HQd, YSI, Shanghai Leici, Sanxin
### 2. Spectrophotometric Colorimetric Type (requires pre-made reagents, some with digestion)
**Can measure: COD, ammonia nitrogen, total phosphorus, total nitrogen, total chromium, hexavalent chromium, residual chlorine, total chlorine, heavy metals and dozens of other indicators.**
- Principle: spectrophotometric method, water sample added with pre-made reagent for color development; COD/total phosphorus/total nitrogen require the instrument's built-in digestion module for high-temperature digestion, measuring absorbance to convert concentration, in compliance with national standard methods.
- Advantages: can measure the four conventional sewage discharge parameters, data meets environmental screening requirements;
- Disadvantages: consumes pre-made reagents, some items require digestion, taking several minutes.
>
> Representative: Lianhua Technology, Suijing, Luheng, Tianer and other domestic portable digestion integrated machines
## Common Detection Parameters
1. Electrochemical five parameters: **pH, dissolved oxygen DO, conductivity, ORP, temperature** (mandatory for surface water and groundwater)
2. Sewage characteristic parameters: **COD, ammonia nitrogen, total phosphorus, total nitrogen (four sewage parameters)**
3. Others: turbidity, suspended solids, residual chlorine, total chlorine, nitrite, heavy metals (copper, zinc, lead, cadmium), etc.
## Main Features
1. Portability: carrying case/handheld, lithium battery powered, operates outdoors without mains electricity;
2. Data: large screen display, stores tens of thousands of data sets, USB export; high-end supports GPS positioning, 4G/Wi-Fi upload, on-site printing, photo evidence, suitable for environmental law enforcement emergency monitoring;
3. Protection: main unit IP67, electrode IP68 waterproof, usable in field rain;
4. Calibration: supports single-point/multi-point calibration, electrode models require periodic electrode calibration.
## Application Scenarios
- Environmental emergency monitoring, river/reservoir surface water inspection;
- On-site screening at sewage treatment plant outlets;
- Aquaculture, groundwater, drinking water rapid testing;
- Scientific research field sampling, environmental law enforcement on-site testing;
- Industrial wastewater on-site investigation.
## Selection Key Points
1. **Clarify needs**
- Only measuring basic physical and chemical parameters like pH, dissolved oxygen, conductivity: choose **electrochemical electrode model**, no reagents, fast;
- Need to measure COD, total phosphorus, total nitrogen: choose **spectrophotometric portable model with digestion**, need to purchase matching pre-made reagents.
2. Confirm whether the method complies with national standard HJ; for law enforcement scenarios, prioritize equipment with relevant certifications.
3. Consumable cost: electrodes need periodic replacement; spectrophotometric models consume pre-made reagents long-term.
4. Protection, battery life, data export, whether GPS, printing, cloud upload are needed.
Main Application Areas
- Environmental Monitoring — Rapid assessment of water quality in rivers, lakes, and streams for pollution detection and ecological studies.
- Wastewater Treatment — On-site verification of effluent quality and process control in municipal and industrial wastewater treatment plants.
- Emergency Response — Quick water safety screening during natural disasters, chemical spills, or other emergencies to ensure public health.
- Aquaculture — Monitoring water parameters in fish farms and hatcheries to maintain optimal conditions for aquatic life.
Keywords:portable water quality analyzer, multi-parameter water tester, handheld water quality meter, field water testing equipment, water quality monitoring device, AMT-101, portable water quality meter, water quality analyzer for field use