Vector Network Analyzer - GA3623
• 10.4-inch TFT color LCD display, touch screen.
• Windows XP operation, Chinese and English interfaces, with a highly vibration-resistant solid-state drive.
• Unique calibration methods including response calibration, 1-port calibration, enhanced response calibration, and 2-port calibration.
• Supports mechanical calibration kits, port extension functions, cable structure return loss and fault location functions.
• Dual-port testing, can simultaneously test 4 S-parameters (S11, S21, S12, S22) of two-port devices, limit testing, ripple testing.
• 4 channels/4 traces/9 markers.
• Has USB, LAN, RS232, keyboard PS/2 interface, mouse PS/2 interface, external VGA display interface.
• Supports VBA macro programming for software function expansion, can complete automatic testing without an external host PC. Control the network analyzer through LAN and other programmable interfaces to complete automatic testing. The programming commands are fully compatible with Agilent E5061/E5062A network analyzers.
• Stable and reliable performance, self-developed 'electrostatic protection device' can effectively prevent electrostatic damage during instrument use, with good anti-burnout capability.
• Scan speed 25ms (201 points, IF bandwidth 30KHz). Fast power-on and power-off speed.
Product Introduction
I. Description of GA3623 Vector Network Analyzer
The GA3623 vector network analyzer consists of a high-precision synthesized signal source with new technology, a narrowband receiver, a high-speed embedded computer, and the Windows operating system. It features high measurement accuracy, fast measurement speed, and strong measurement adaptability. The Windows operating interface is more user-friendly, making it suitable for measurement applications in mass production and manufacturing of RF components and equipment.
The GA3623 vector network analyzer has powerful measurement capabilities.
II. Features of GA3623 Vector Network Analyzer
• 10.4-inch TFT color LCD display, touch screen.
• Windows XP operation, Chinese and English interfaces, with a highly vibration-resistant solid-state drive.
• Unique calibration methods including response calibration, 1-port calibration, enhanced response calibration, and 2-port calibration.
• Supports mechanical calibration kits, port extension functions, cable structure return loss and fault location functions.
• Dual-port testing, can simultaneously test 4 S-parameters (S11, S21, S12, S22) of two-port devices, limit testing, ripple testing.
• 4 channels/4 traces/9 markers.
• Has USB, LAN, RS232, keyboard PS/2 interface, mouse PS/2 interface, external VGA display interface.
• Supports VBA macro programming for software function expansion, can complete automatic testing without an external host PC. Control the network analyzer through LAN and other programmable interfaces to complete automatic testing. The programming commands are fully compatible with Agilent E5061/E5062A network analyzers.
• Stable and reliable performance, self-developed 'electrostatic protection device' can effectively prevent electrostatic damage during instrument use, with good anti-burnout capability.
• Scan speed 25ms (201 points, IF bandwidth 30KHz). Fast power-on and power-off speed.
III. Parameters of GA3623 Vector Network Analyzer
Frequency range: 300kHz - 3GHz
Frequency accuracy: 5ppm (at 23°C ± 5°C)
Frequency resolution: 1Hz
Output level: -45dBm to +10dBm
Level accuracy: ±0.8dB (at 0dBm, 50MHz)
Level resolution: 0.05dB
Phase noise: -67dBc/Hz @10kHz
Harmonics and non-harmonics: < -30dBc (at 0dBm)
IF bandwidth: 10Hz - 30kHz
Directivity: 44dB
Dynamic range: 110dB