Aqualabo OPTOD Dissolved Oxygen Sensor PF-CAP-C-00160
Aqualabo OPTOD Dissolved Oxygen Sensor

Aqualabo OPTOD Dissolved Oxygen Sensor - PF-CAP-C-00160

Low operating costs due to reduced maintenance (no electrolyte replacement).
Low drift, better calibration intervals
No polarization voltage • High accuracy even at low concentrations • Fast response time
No minimum flow rate (no oxygen consumption)

Product Model: PF-CAP-C-00160

Product Introduction

Aqualabo OPTOD Dissolved Oxygen SensorPF-CAP-C-00160 Description:

The OPTOD dissolved oxygen sensor uses fluorescence optical measurement technology, providing accurate and reliable measurement data without calibration. No consumables and maintenance required, the OPTOD sensor offers immediate return on investment. All that is needed is to replace the DO disk every 2 years. Since it does not consume oxygen, the OPTOD sensor can be used in all media, even with very weak water flow.



Aqualabo OPTOD Dissolved Oxygen SensorPF-CAP-C-00160 Features:

• Low operating costs due to reduced maintenance (no electrolyte replacement).

• Low drift, better calibration intervals

• No polarization voltage • High accuracy even at low concentrations • Fast response time

• No minimum flow rate (no oxygen consumption)

Thanks to the integrated preamplifier and digital signal processing, the sensor has excellent anti-interference capability. Dissolved oxygen measurements are automatically compensated for temperature, air pressure, and salinity (salt content), transmitted via digital interface without interference from connected display devices and controllers. The membrane cap is easy to replace, meaning the sensor is easy to maintain. Calibration data is stored directly in the sensor electronics. As a result, plug-and-play is possible without recalibration. The sensor also includes a logbook of the last 10 successful calibrations in the form of a ring buffer.



Aqualabo OPTOD Dissolved Oxygen SensorPF-CAP-C-00160 Applications:

The compact and rugged stainless steel or titanium sensor is especially suitable for the following typical application areas:

• Industrial and municipal wastewater treatment plants

• Wastewater management (nitrification and denitrification)

• Surface water monitoring

• Fish farming, aquaculture

• Drinking water monitoring


Aqualabo OPTOD Dissolved Oxygen SensorPF-CAP-C-00160 Specifications:

Measurement Principle

Optical measurement via fluorescence

Range

0,00~ 20,00 mg/L  

0,00~ 20,00 ppm  

0-200%

Resolution

0,01

Accuracy

+/- 0,1mg/L  

Accuracy

+/- 0,1 ppm

+/- 1 %

Response Time


Less than 90% of value within 60 seconds

Range (Temperature)


0.00~ 50.00 °C