Home chevron_right Instruments & Meters chevron_right CO Alarms 
Carbon Monoxide Alarm (CO Alarm) VST-C598IH
Carbon Monoxide Alarm (CO Alarm)

Carbon Monoxide Alarm (CO Alarm) - VST-C598IH

Alarms at different times based on concentration changes
Quick-install mounting bracket for easy installation
Simple AC connector for easy installation

Model: VST-C598IH

Product Introduction

1. Carbon Monoxide Alarm (CO Alarm) VST-C598IH Description:

AC/DCCarbon Monoxide Alarm

Environmentally friendly non-radioactive technology

Alarms at different times based on concentration changes

Quick-install mounting bracket for easy installation

Simple AC connector for easy installation

Tamper-resistant features for fitting and battery

Interconnects up to 40 CO, heat, and/or smoke alarms

Tri-color LED indicator (fault, alarm, and AC power indicators)

Low battery and missing battery warning indicators

Silence/Test button

Automatic reset

CE certified, compliant with EN50291:2010


2. Carbon Monoxide Alarm (CO Alarm) VST-C598IH Parameters:

Product Name

VST-C598IH

Power Supplies

220-240V AC 50Hz and 9V DC battery backup

Rated Power

Operating voltage: 220-240V AC, 50Hz

Operating current (typical): 60mA

Operating voltage: 9V DC

Operating current (typical): 15uA (standby); 20mA (alarm)

CO Sensitivity

At 50ppm, the unit must alarm within 60-90 minutes.

At 100ppm, the unit must alarm within 10-40 minutes.

At 300ppm, the unit must alarm within 3 minutes.

 

Response Time

4 minutes

Detection Method

Electrochemical

Temperature

5℃to 38℃

Ambient Humidity

15% to 90% relative humidity

Dimensions

40mmX112mm