Product Introduction
Color screen display, touch screen settings, easy operation
Adopts a high-precision negative oxygen ion measurement unit, with good long-term stability and small drift
Adopts a dedicated 485 circuit, standard ModBus-RTU communication protocol, communication address and baud rate are configurable
Built-in battery, supports external 10~30V DC wide voltage range power supply
Comes with storage function by default and supports USB flash drive export
Optional formaldehyde sensor, PM2.5/10 sensor, 1-channel temperature and humidity sensor, TVOC sensor
| DC Power Supply (Default) | DC10-30V/battery power supply | |
| Battery capacity | 4000mAh | |
| Data storage | 65535 data records | |
| Working Environment | Temperature -20℃-50℃; humidity <95%RH without condensation | |
| Charging time | ≤4h | |
| Battery life | 10h | |
| Negative oxygen ion parameters | Default range | 0~8 million pcs/cm3 |
| Minimum resolution | 10 pcs/cm3 | |
| Typical accuracy | ±15% | |
| Data update frequency | 1Hz | |
| Ion mobility | 0.4cm2/(V*S) | |
| Ion migration error | ±5% | |
| Temperature | Default range | -40℃~60℃ |
| Accuracy | ±0.5℃(25℃) | |
| 分辨率 | ≤0.1℃/y | |
| Humidity | Default range | 0%RH-100%RH |
| Accuracy | ±3%RH(60%RH,25℃) | |
| 分辨率 | ≤1%RH/y | |
| PM10/PM2.5 | Default range | 0~1000μg/m3 |
| Accuracy | Particle counting efficiency: 50%@0.3μm,98%@>=0.5μm。 PM2.5 accuracy: ±3%FS (@100μg/m3、25℃) |
|
| 分辨率 | 1μg/m3 | |
| Formaldehyde | Default range | 0~2ppm |
| Typical accuracy | ±0.025ppm or ±20%FS, whichever is greater | |
| 分辨率 | 0.001ppm | |
| TVOC | Default range | 0~60000ppb |
| Accuracy | 15%FS(@C2H6O,0.5ppm,25℃,50%RH) | |
| 分辨率 | 1ppb | |
Main Application Areas
- Negative Ion Coatings — Measuring negative oxygen ion concentration in various negative ion coatings to ensure product quality and performance.
- Negative Ion Fabrics — Testing negative oxygen ion levels in textiles and fabrics for health and wellness product development.
- Indoor Air Quality Monitoring — Assessing negative oxygen ion concentration in indoor environments to evaluate air quality and ion balance.
- Material Research — Supporting research and development of new negative ion materials by providing accurate ion concentration data.
- Quality Control — Ensuring consistent negative oxygen ion output in manufactured products through regular testing and verification.
Keywords:negative oxygen ion detector, benchtop ion detector, negative ion concentration meter, air ion tester, negative ion monitor, oxygen ion analyzer, ion measurement device, industrial ion detector