Home chevron_right Sensors chevron_right Gas Sensor 
Benchtop negative oxygen ion detector AMT/RS-NEGO-N01-5
Benchtop negative oxygen ion detector

Benchtop negative oxygen ion detector - AMT/RS-NEGO-N01-5

Benchtop negative oxygen ion detector

Product Model: AMT/RS-NEGO-N01-5

Product Introduction

Color screen display, touch screen settings, easy operation
Adopts a high-precision negative oxygen ion measurement unit, with good long-term stability and small drift
Adopts a dedicated 485 circuit, standard ModBus-RTU communication protocol, communication address and baud rate are configurable
Built-in battery, supports external 10~30V DC wide voltage range power supply
Comes with storage function by default and supports USB flash drive export
Optional formaldehyde sensor, PM2.5/10 sensor, 1-channel temperature and humidity sensor, TVOC sensor

DC Power Supply (Default) DC10-30V/battery power supply
Battery capacity 4000mAh
Data storage 65535 data records
Working Environment Temperature -20℃-50℃; humidity <95%RH without condensation
Charging time ≤4h
Battery life 10h
Negative oxygen ion parameters Default range 0~8 million pcs/cm3 
Minimum resolution 10 pcs/cm3
Typical accuracy ±15%
Data update frequency 1Hz
Ion mobility 0.4cm2/(V*S)
Ion migration error ±5%
Temperature Default range -40℃~60℃
Accuracy ±0.5℃(25℃)
分辨率 ≤0.1℃/y
Humidity Default range 0%RH-100%RH
Accuracy ±3%RH(60%RH,25℃)
分辨率 ≤1%RH/y
PM10/PM2.5 Default range 0~1000μg/m3
Accuracy Particle counting efficiency:
50%@0.3μm,98%@>=0.5μm。
PM2.5 accuracy: ±3%FS (@100μg/m3、25℃)
分辨率 1μg/m3
Formaldehyde Default range 0~2ppm
Typical accuracy ±0.025ppm or ±20%FS, whichever is greater
分辨率 0.001ppm
TVOC Default range 0~60000ppb
Accuracy 15%FS(@C2H6O,0.5ppm,25℃,50%RH)
分辨率 1ppb

Main Application Areas

  • Negative Ion Coatings — Measuring negative oxygen ion concentration in various negative ion coatings to ensure product quality and performance.
  • Negative Ion Fabrics — Testing negative oxygen ion levels in textiles and fabrics for health and wellness product development.
  • Indoor Air Quality Monitoring — Assessing negative oxygen ion concentration in indoor environments to evaluate air quality and ion balance.
  • Material Research — Supporting research and development of new negative ion materials by providing accurate ion concentration data.
  • Quality Control — Ensuring consistent negative oxygen ion output in manufactured products through regular testing and verification.

Keywords:negative oxygen ion detector, benchtop ion detector, negative ion concentration meter, air ion tester, negative ion monitor, oxygen ion analyzer, ion measurement device, industrial ion detector